Cutmaster 102 – Tweco 102 Cutmaster User Manual

Page 21

Advertising
background image

CUTMASTER 102

Manual 0-4997

INTRODUCTION

2T-3

B. Gas Distribution

The single gas used is internally split into plasma and

secondary gases.

The plasma gas flows into the torch through the negative

lead, through the starter cartridge, around the electrode,

and out through the tip orifice.

The secondary gas flows down around the outside of the

torch starter cartridge, and out between the tip and shield

cup around the plasma arc.

C. Pilot Arc

When the torch is started a pilot arc is established between

the electrode and cutting tip. This pilot arc creates a path

for the main arc to transfer to the work.

D. Main Cutting Arc

DC power is also used for the main cutting arc. The nega-

tive output is connected to the torch electrode through

the torch lead. The positive output is connected to the

workpiece via the work cable and to the torch through a

pilot wire.

E. Parts - In - Place (PIP)

The torch includes a 'Parts - In - Place' (PIP) circuit. When

the shield cup is properly installed, it closes a switch. The

torch will not operate if this switch is open.

A-02997

Torch Trigger

PIP Switch

Shield Cup

To Control

Cable Wiring

Torch Switch

Parts - In - Place Circuit Diagram for Hand Torch

PIP Switch

Shield Cup

To ATC

CNC Start

PIP Switch

Shield Cup

PIP Switch

Shield Cup

Remote Pendant

Automation Torch

To ATC

To ATC

Art # A-08168

Parts - In - Place Circuit Diagram for Machine Torch

Advertising