Cutmaster 102 – Tweco 102 Cutmaster User Manual

Page 49

Advertising
background image

CUTMASTER 102

Manual 0-4997

OPERATION

4T-15

Type Torch: SL100 With Shielded Tip

Type Material: Mild Steel

Type Plasma Gas: Air

Type Secondary Gas: Single Gas Torch

Thickness

Tip

Output

Amperage Speed (Per Minute)

Standoff

Plasma Gas Press

Flow (CFH)

Pierce

Pierce Height

Inches mm (Cat. No.) Volts(VDC)

(Amps)

Inches

Meters

Inches mm

psi*

bar

Plasma Total** Delay (Sec) Inches mm

0.060 1.5

9-8210

124

60

250

6.35

0.19 4.8

70

4.8

90

245

0.00

0.2

5.1

0.075 1.9

9-8210

126

60

237

6.02

0.19 4.8

70

4.8

90

245

0.10

0.2

5.1

0.120 3.0

9-8210

126

60

230

5.84

0.19 4.8

70

4.8

90

245

0.10

0.2

5.1

0.135 3.4

9-8210

128

60

142

3.61

0.19 4.8

70

4.8

90

245

0.10

0.2

5.1

0.188 4.8

9-8210

128

60

125

3.18

0.19 4.8

70

4.8

90

245

0.20

0.2

5.1

0.250 6.4

9-8210

123

60

80

2.03

0.19 4.8

70

4.8

90

245

0.30

0.2

5.1

0.375 9.5

9-8210

132

60

34

0.86

0.19 4.8

70

4.8

90

245

0.50

0.2

5.1

0.500 12.7 9-8210

137

60

23

0.58

0.19 4.8

70

4.8

90

245

0.75

0.2

5.1

0.625 15.9 9-8210

139

60

14

0.36

0.19 4.8

70

4.8

90

245

NR

NR

NR

0.750 19.1 9-8210

145

60

14

0.36

0.19 4.8

70

4.8

90

245

NR

NR

NR

1.000 25.4 9-8210

156

60

4

0.10

0.19 4.8

70

4.8

90

245

NR

NR

NR

Type Torch: SL100 With Shielded Tip

Type Material: Stainless Steel

Type Plasma Gas: Air

Type Secondary Gas: Single Gas Torch

Thickness

Tip

Output

Amperage Speed (Per Minute)

Standoff

Plasma Gas Press

Flow (CFH)

Pierce

Pierce Height

Inches mm (Cat. No.) Volts(VDC)

(Amps)

Inches

Meters

Inches mm

psi*

bar

Plasma Total** Delay (Sec) Inches mm

0.06

1.5 9-8210

110

60

165

4.19

0.13 3.2

70

4.8

90

245

0.00

0.20 5.1

0.075 1.9 9-8210

116

60

155

3.94

0.13 3.2

70

4.8

90

245

0.10

0.20 5.1

0.120 3.0 9-8210

115

60

125

3.18

0.13 3.2

70

4.8

90

245

0.10

0.20 5.1

0.135 3.4 9-8210

118

60

80

2.03

0.13 3.2

70

4.8

90

245

0.10

0.20 5.1

0.188 4.8 9-8210

120

60

75

1.91

0.13 3.2

70

4.8

90

245

0.20

0.20 5.1

0.250 6.4 9-8210

121

60

60

1.52

0.13 3.2

70

4.8

90

245

0.30

0.20 5.1

0.375 9.5 9-8210

129

60

28

0.71

0.13 3.2

70

4.8

90

245

0.50

0.20 5.1

0.500 12.7 9-8210

135

60

17

0.43

0.19 4.8

70

4.8

90

245

0.75

0.20 5.1

0.625 15.9 9-8210

135

60

14

0.36

0.19 4.8

70

4.8

90

245

NR

NR

NR

0.750 19.1 9-8210

142

60

10

0.25

0.19 4.8

70

4.8

90

245

NR

NR

NR

Type Torch: SL100 With Shielded Tip

Type Material: Aluminum

Type Plasma Gas: Air

Type Secondary Gas: Single Gas Torch

Thickness

Tip

Output

Amperage Speed (Per Minute)

Standoff

Plasma Gas Press

Flow (CFH)

Pierce

Pierce Height

Inches mm (Cat. No.) Volts(VDC) (Amps)

Inches

Meters

Inches mm

psi*

bar

Plasma Total** Delay (Sec) Inches mm

0.060 1.5 9-8210

105

60

350

8.89

0.13 3.2

70

4.8

90

245

0.00

0.20

5.1

0.075 1.9 9-8210

110

60

350

8.89

0.13 3.2

70

4.8

90

245

0.10

0.20

5.1

0.120 3.0 9-8210

110

60

275

6.99

0.13 3.2

70

4.8

90

245

0.10

0.20

5.1

0.188 3.4 9-8210

122

60

140

3.56

0.13 3.2

70

4.8

90

245

0.20

0.20

5.1

0.250 6.4 9-8210

134

60

80

2.03

0.19 4.8

70

4.8

90

245

0.30

0.20

5.1

0.375 9.5 9-8210

140

60

45

1.14

0.19 4.8

70

4.8

90

245

0.50

0.20

5.1

0.500 12.7 9-8210

144

60

26

0.66

0.19 4.8

70

4.8

90

245

0.80

0.20

5.1

0.625 15.9 9-8210

145

60

19

0.48

0.19 4.8

70

4.8

90

245

NR

NR

NR

0.750 19.1 9-8210

150

60

15

0.38

0.19 4.8

70

4.8

90

245

NR

NR

NR

Advertising