DISASSEMBLY

DANgER !

Before opening any Viking pump liquid

chamber (pumping chamber, reservoir,

relief valve adjusting cap fitting, etc.)

Be sure:
1. That any pressure in the chamber has

been completely vented through the

suction or discharge lines or other

appropriate openings or connections.

2. That the driving means (motor,

turbine, engine, etc.) has been “locked

out” or made non-operational so that

it cannot be started while work is

being done on pump.

3. That you know what liquid the

pump has been handling and the

precautions necessary to safely

handle the liquid. Obtain a material

safety data sheet (MSDS) for the

liquid to be sure these precautions

are understood.

failure to follow above listed

precautionary measures may result in

serious injury or death.

fIgURE 14

Size LS

PRESSURE RELIEf VALVE

INSTRUCTIONS

LIST Of PARTS

1. Valve Cap

6. Valve Body

2. Adjusting Screw

7. Valve Spring

3. Lock Nut

8. Poppet

4. Spring Guide

9. Cap Gasket

5. Bonnet

10. Bonnet

When installing carbon graphite bushings, extreme care

must be taken to prevent breaking. Carbon graphite is a

brittle material and easily cracked. If cracked, the bushing will

quickly disintegrate. Using a lubricant and adding a chamfer

on the bushing and the mating part will help in installation.

The additional precautions listed below must be followed for

proper installation:
1. A press must be used for installation.
2. Be certain bushing is started straight.
3. Do not stop pressing operation until bushing is in proper

position. Starting and stopping will result in a cracked

bushing.

4. Check bushing for cracks after installation.
Carbon graphite bushings with extra interference fits are

frequently furnished for high temperature operation. These

bushings must be installed by a shrink fit.
1. Heat bracket or idler to 750 °F.
2. Install cool bushings with a press.
3. If facilities are not available to reach 750 °F. temperature,

it is possible to install with

450 °F. temperature; however,

the lower the temperature, the greater the possibility of

cracking bushing.

Consult factory with specific questions on high temperature

applications.

Refer to Engineering Service Bulletin ESB-3.

INSTALLATION Of CARBON

gRAPHITE BUSHINgS

fIgURE 15