SECTION TSM 141.2

ISSUE

F

PAGE 8 OF 12

gREASE fITTINg

SETSCREWS

OUTER END CAP

LOCKWASHER

LOCKNUT

OUTER

SPACER

COLLAR

OUTER LIP

SEAL

BRACKET

BALL BEARINg

INNER

LIP SEAL

INNER SPACER

COLLAR

HALf

ROUND

RINgS

INNER

END CAP

NYLON INSERT

fIgURE 7

fIgURE 6 - STANDARD MECHANICAL SEAL

RIgHT SIDE

Of PUMP

SPRINg ADAPTER

SEAL ACCESS HOLE (fOR SETSCREWS)

SEAL SEAT gASKET

SEAL HOLDER

SET COLLAR

SEAL

SEAT

MECHANICAL SEAL (ROTARY MEMBER)

SEAL

HOLDER

PLATE

ASSEMBLY

Standard Mechanical Seal

(Synthetic Rubber Bellows Type)

9.

Loosen the four setscrews over the outer and inner end

caps. Remove both end caps, spacer collars and ball

bearing.

Refer to figure 7. The inner end cap can be

removed through the side openings in the bracket.

10. Clean all parts thoroughly and examine for wear or

damage. Check lip seals, ball bearing, bushing and idler

pin and replace if necessary. Check all other parts for

nicks, burrs, excessive wear and replace if necessary.

Wash bearings in clean solvent. Blow out bearings with

compressed air. Do not allow bearings to spin; turn them

slowly by hand. Spinning bearings will damage race

and balls. Make sure bearings are clean, then lubricate

with non-detergent SAE 30 weight oil and check for

roughness. Roughness can be determined by turning

outer race by hand.

Be sure shaft is free from nicks, burrs and foreign

particles that might damage bracket bushing. Scratches

on shaft in seal area will provide leakage paths under

mechanical seal.

11.

Casing can be checked for wear or damage while

mounted on bracket.

The seal used in this pump is simple to install and good

performance will result if care is taken during installation.
The principle of the mechanical seal is contact between the

rotary and stationary members. These parts are lapped to

a high finish and their sealing effectiveness depends on

complete contact.
Viking furnishes a number of heavy-duty pumps with

special mechanical seals installed in the packing end of the

pump. These special seals are not discussed in

TSM141.2.

Information is available by contacting the factory. When

requesting special seal information, be sure to give pump

model number and serial number.
1. Install bracket bushing. If bracket bushing has a

lubrication groove, install bushing with groove at 6:00

o’clock position in bracket. If carbon graphite,

Refer to

Installation of Carbon graphite Bushings, page 11.

2. Coat rotor shaft with non-detergent SAE 30 weight oil.

Start end of shaft in bracket bushing and turn from right

to left, slowly pushing until the ends of the rotor teeth are

just below the face of the casing.

3. Using a .015 inch head gasket, install head and idler

assembly on pump. Pump head and casing were marked

before disassembly to insure proper reassembly. If not, be

sure idler pin, which is offset in pump head, is positioned

toward and equal distance between port connections to

allow for proper flow of liquid through pump.
If pump is equipped with jacketed head plate, install at

this time along with new gasket.
Tighten head capscrews evenly.
If pump was equipped with a relief valve and it was

removed during disassembly, install a head with new

gaskets. Relief valve adjusting screw cap must always

point toward suction port.

Refer to figures 1, 2 and 3 on

page 1. For relief valve repair or adjustments,

Refer to

Pressure Relief Valve Instructions, page 11.

4. Clean rotor shaft and bracket seal housing bore. Be sure

they are free of dirt, grit and scratches. Gently radius

leading edge of shaft diameter over which seal must be

placed.

5. Install seal set collar. Examine set collar for burrs or

scratches, and setscrews are withdrawn to prevent

shaft from being scratched when set collar is installed.

Place set collar onto shaft, push into seal chamber until

centerline of setscrews coincides with centerline of

tapped seal access holes on right side of bracket (viewed

from shaft end).
Tighten all setscrews securely to shaft.

Refer to figure

8.

6. Sealing faces on mechanical seals should not be

touched with anything but fingers or a clean cloth. A

tapered sleeve is available, at extra cost, for Q, QS and

M pumps from Viking Pump for seal installation on shaft.

Refer to figure 9.
LS pump shaft is tapered and an installation sleeve is

not available.