Page 18

5.2

Single Mechanical Seal.

Item Number

Description

Material

Quantity

4.01.03

Static Face

Silicon Carbide

2

4.01.04

O-ring

EPDM / VITON

4

4.01.05

Housing

316 S11 St. Steel

2

4.01.06

Wave Spring

St. Steel

2

4.01.07 *

Slinger O-ring

EPDM / VITON

2

4.01.08

M8 Dog Point Grub Screw

316 St. Steel

2

4.01.09 *

1/8 BSPT Hex Plug

316 St. Steel

2

*

- Not Shown

Install Slinger O-Ring (4.01.07) onto the shaft ensuring the o-ring is all the way up the

shaft and against the pump body bore face. This is also visible through the slots in

the sides of the pump body.

Install external o-rings (4.01.04).

Install the seal housing into the pump assembly. Aligning the flush holes with the

tapings in the pump body.