5.2
Single Mechanical Seal.
Item Number
Description
Material
Quantity
4.01.03
Static Face
Silicon Carbide
2
4.01.04
O-ring
EPDM / VITON
4
4.01.05
Housing
316 S11 St. Steel
2
4.01.06
Wave Spring
St. Steel
2
4.01.07 *
Slinger O-ring
EPDM / VITON
2
4.01.08
M8 Dog Point Grub Screw
316 St. Steel
2
4.01.09 *
1/8 BSPT Hex Plug
316 St. Steel
2
*
- Not Shown
•
Install Slinger O-Ring (4.01.07) onto the shaft ensuring the o-ring is all the way up the
shaft and against the pump body bore face. This is also visible through the slots in
the sides of the pump body.
•
Install external o-rings (4.01.04).
•
Install the seal housing into the pump assembly. Aligning the flush holes with the
tapings in the pump body.