Page 21

Install the flush locking adapter o-ring (4.01.12) onto the adapter (4.01.11).

Install the flush locking adapter (4.01.12) such that the end of the component is

locking the seal housing in position.

Install the primary o-ring (4.01.04) onto the Static Seal (4.01.03).

Install the static seal face (4.01.03) aligning the slots in the seal face with the anti-

rotation pins in the seal housing.

Install the rotor and rotary seal face assembly.