3.0 General

The pumping action of the rotary lobe pump principle is generated by the contra-

rotation of two pumping elements (rotors) within a chamber (rotorcase). The rotors

are located on shafts, which in turn are held within the pump body. The shaft

assemblies comprise of the support bearings and the timing gears. The timing gears

transfer the drive from the driven shaft to the lay shaft, synchronising the rotors such

that they rotate without contact with each other.

As the rotors pass the suction port, (see ‘A’), the cavity generated increases creating

a pressure decrease, which induces the media to be pumped to flow into the

rotorcase (‘B’).

The pumped media is carried around the rotorcase by the rotors; (‘C’ and ‘D’) to the

discharge side of the pump (‘E’). Here the cavity decreases and the pumped medium

is discharged from the rotorcase (‘F’).

The maximum pressure and speed operating parameters are shown below. In

practice these may be limited due to the nature of the product to be pumped and/or

F

E

D

C

B

A

Advertising