SECTION TSM 285

ISSUE

A

PAGE 11 OF 36

Note: Care should be taken not to exceed the

lower of either the pump’s maximum pressure

rating or the system design pressure.
- To use the air lift system, the regulated air

supply must be routed through a change-over

valve in order to transfer air from the relief valve

load air chamber, connection ‘A’, to the lift air

chamber, connection ‘B’, while depressurizing

the load chamber and vice versa. The change-

over valve will actuate the air lift which will lift

when the air supply is diverted to connection

‘B’, and will close, restoring normal relief valve

operation, when the air supply is diverted back

to connection ‘A’.

figure 11

Spring Loaded Integral Pressure Relief Valve

CP10, CP20, CP30, CP40

figure 12

Spring Loaded Integral Pressure Relief Valve

with Manual Lift

CP10, CP20 and CP30

figure 13

Spring Loaded Integral Pressure Relief Valve with Air Lift

CP10, CP20 and CP30

figure 14

Air Loaded Integral Pressure Relief Valve with Air Lift

CP10, CP20, CP30 and CP40

DANGER !

Under no circumstances should any

attempt be made to dismantle a pressure

relief valve which has not had the spring

pressure relieved, is still connected to a

pressurized air supply, or is mounted on a

pump that is operating. Serious personal

injury or pump damage may occur.

!

!

!

WARNING