Viking Pump TSM285: Classic+ Lobe Pump User Manual

Page 16

Advertising
background image

SECTION TSM 285

ISSUE

A

PAGE 16 OF 36

- CP10 Pumps Only - Timing marks and gear marks ‘D’ and

‘L’ on gears (5.09) should be visible when viewed on the

drive end of the drive shaft.

- CP20 and CP30 Pumps Only - Timing marks and gear

marks ‘D’ and ‘L’ on gears (5.09) should be visible when

viewed on the drive end of the shafts (5.01 and 5.02), and

the tapered shoulder on the gear (5.09) should face the

bearings (5.05).

- Install gears (5.09) to shafts (5.01 and 5.02). Gear marked

‘D’ should be installed to drive shaft (5.01). Gear marked

‘L’ should be installed to lay shaft (5.02) ensuring correct

alignment of timing marks, see Figure 26.

- CP10 and CP20 Pumps Only - Install tab washers (5.11)

and lock nuts (5.12) tightened to correct torque, refer to

section 8.2. Do not secure tab washers (5.11).

- CP30 Pumps Only - Install locknuts (5.12) and tighten to

correct torque (refer to section 8.2).

Install, but do not tighten lock-screws (5.12) which are fitted

in the locknuts (5.12).

- After adjusting shim (5.04) check rotor front face alignment

and rolling torque.

- Remove rotor retainers’ (2.02) and rotors (2.01).
- CP10 Pumps Only - Install spacers (5.16) and gear keys

(5.10) to shafts (5.01 and 5.02).

- CP20 and CP30 Pumps Only - Install gear keys (5.10) to

shafts (5.01 and 5.02).

- Install rotors (2.01) and rotor retainers (2.02)
- Check mesh clearance against the Clearance Chart (refer to

section 8.1).

- To adjust mesh clearance shims (5.08) will need to be inserted

between the spacer (5.16) and the gear (5.09). As a guide for

a mesh clearance change of one unit (say 0.1mm or 0.004”),

shims (5.08) of four units’ thickness (say 0.4mm or 0.016”)

need to be inserted. Further, for clockwise movement of the

rotor (when viewed from the rotor end) insert shim (5.08) in

between the spacer (5.16) on the CP10; or bearing (5.05) on

the CP20 and CP30; and the gear (5.09) having a right hand

helix, and vice versa, see Figure 27.

- Having installed shim (5.08) ensure lock nuts (5.12) are

tightened to correct torque (refer to section 8.2), before

checking mesh clearance (refer to section 8.1).

- CP10 and CP20 Pumps Only - Having achieved optimum

mesh clearances the tab washers’ (5.11) can be secured.

- CP30 Pump Only - Having achieved optimum mesh

clearances the lock screws in the locknuts (5.12) can be

secured.

- Remove rotor retainers’ (2.02) and rotors (2.01).
- Install bearing (6.02) inner races to shafts (5.01 and 5.02),

positioning against shoulder on shaft.

- Install inner retaining rings (6.01), bearing (6.02) outers, outer

retaining rings (6.01), lipseal (6.03), blanking cap (6.04), filler

plug (6.10), sight glass (6.07) and drain plug (6.09) to cover

(6.00).

- Install cover (6.00) to bearing housing (4.01) with gasket

(6.05), locating on dowels (6.06), and secure with screws

(6.11) tightened to correct torque, refer to section 8.2.

4.1.5 CP10, CP20 AND CP30 CASING,

ROTOR AND HEAD ASSEMbLy

- see Figure 15 for CP10.
- see Figure 16 for CP20 and CP30.
- Install casing (3.01) to bearing housing (4.01) locating on

dowels (4.03).

- CP10 Pump Only - Secure casing (3.01) in position with

nuts (1.03) using four temporary spacers (12mm long x 9mm

bore or 0.472” long x 0.354” bore).

figure 25

Rotor / bearing abutment setting

Advertising