2.7 STANDARD PUMP

COMPONENT TERMS

3.0 GENERAL
3.1 CLASSIC+ PUMPING PRINCIPAL

The pumping action of the rotary lobe pump principle is

generated by the contra rotation of two pumping elements

(rotors) within a chamber (casing) - see Figure 5. The rotors are

located on shafts, which in turn are mounted within an external

gearbox and supported by the bearings; the timing gears are

also located on the shafts. The timing gears transfer the energy

from the drive shaft to the driven shaft, synchronizing the rotors

such that they rotate without contact with each other.
As the rotors pass the suction port, see Figure 5a, the cavity

generated increases creating a pressure decrease, which

induces the pumped medium to flow into the casing.
The pumped medium is carried around the casing by the rotors;

see Figure 5b and 5c, to the discharge side of the pump, Figure

5d. Here the cavity decreases and the pumped medium is

discharged from the casing, Figure 5e.
For pump component terms, see Figure 4.

3.2 CLASSIC+ RANGE OPERATING

PARAMETERS

The maximum pressure and speed operating parameters are

given in Figure 6. In practice these may be limited due to the

nature of the product to be pumped and/or design of the system

in which the pump is to be installed. Consult Viking Pump or

your Viking Pump distributor for assistance.
The operating temperature limit of the pump is determined

by the rotor clearance. For the CP10, CP20, CP30 and CP40

series pumps there are three rotor clearance bands (class A,

B and C), and two (class B and D) for the CP50 series pumps.

If the system or product characteristics are to

be changed from the original application for

which the pump was selected, Viking Pump or

their authorized distributor should be consulted

to ensure the pump is suitable for the new

application.

The pump should not be subjected to sudden temperature

changes to avoid the risk of damage from sudden expansion/

contraction of components. Care should be taken when

selecting pumps for handling liquids containing abrasive

particles as these may cause wear of pump head components.

For advice or assistance contact Viking Pump or your Viking

Pump distributor.

ROTORS

FRONT COVER

ROTOR

RETAINER

ROTORCASE

BEARING

HOUSING

FRONT

BEARINGS

GEARBOX

COVER

BREATHER

/FILLER CAP

REAR

BEARINGS

DRIVE

SHAFT

DRIVEN

SHAFT

TIMING

GEARS

figure 4

Pump Component Terms

figure 5

Rotary Lobe Pumping Principle