SECTION TSM 285

ISSUE

A

PAGE 18 OF 36

- Slide casing (3.01) from gearbox (4.01) noting it is located on

dowels (4.03), keep arch shims (4.05) in appropriate sets if

they are to be reused.

4.2.2.2 CP40 CASING

REMOVAL fOR PUMPS

fITTED WITH SINGLE

fLUSHED OR DOUbLE

fLUSHED MECHANICAL

SEALS

- Prior to removal of casing (3.01) remove seal housing screws

(7.10) and separate housing (7.06) from casing (3.01) noting

it is located on dowels (7.09).

- Slide casing from bearing housing (4.01), noting it is located

on dowels (4.03), keep arch shims (4.05) in appropriate sets

if they are to be re-used

Single Flushed Mechanical Seal as shown in Figure 31 and

see sections 5.2.3 for removal and 5.2.4 for replacement.
Double Flushed Mechanical Seal as shown in Figure 32 and

see section 5.2.7 for removal and 5.2.8 for replacement.

4.2.3 CP40 GEARbOX

DISASSEMbLy

(After completing 4.3.1 and 4.3.2) - See Figure 33.
Before proceeding with disassembly of the gearbox remove

product seals; refer to sections 5.0 for Mechanical Seals or

section 6.0 for O-ring seals.
The following procedure describes complete disassembly of

the gearbox, refer to Figure 33.
- Remove drive key (6.12), oil drain (6.09) and breather plugs

(6.10), drain oil into suitable container and retain if later

inspection is required.

- Remove screws (6.11) and gearbox cover (6.00). The

gearbox cover (6.00) is located on dowels (6.06) and sealed

with suitable liquid sealer.

- Remove oil seal (6.03) from gearbox cover (6.00).
- Loosen by 2 full turns all screws in retainer (5.16). Once this is

done, the retainer may release its grip. If it does not become

free, remove the two screws, which differ in color (these may

also have a washer under the head). Once these screws are

removed, tapped holes will be revealed. Insert two jacking

M8 x 40 setscrews into the tapped holes and tighten until the

retainer’s grip is broken. Remove the retainer.

figure 30

O-ring Seal

figure 31

Single flushed Mechanical Seal - CP40