SECTION TSM 285

ISSUE

A

PAGE 30 OF 36

7.1 SINGLE MECHANICAL SEAL

(fOR LOW-PRESSURE

QUENCH OR fLUSH)

See Figure 17 (CP10), Figure 27 (CP20, CP30, CP40) and

Figure 50 (CP50).
Refer to section 4.3.3.
This seal arrangement requires a supply of media to the

outboard side of the mechanical seal to quench or flush the

seal area. The nature of the pumped media and the specific

duty conditions will determine whether a quench or a flush is

required.
A quench provides a static head. The quench media vessel

should be mounted a minimum of 0.5m (1.5 Feet) above

the pump, preferably directly above the seal area. The

interconnecting pipe work should be as straight as possible,

avoiding horizontal runs, and with the minimum number of

bends and restrictions.
For a suitable flush, the media must be supplied at a flow rate

of 4.5 Liters per minute per shaft seal.

Note: The limiting flush or quench pressure

in any application is 0.7 bar (10 psig).

7.2 DOUbLE MECHANICAL SEAL

(fOR HIGH PRESSURE fLUSH)

See Figure 18 (CP10) and Figure 28 (CP20, CP30, CP40) and

Figure 51 (CP50)
Refer to section 4.3.4.
This seal arrangement requires a supply of media to be

circulated between the inboard and outboard mechanical

seals.
The flush media must be supplied at a flow rate of 4.5 Liters per

minute per shaft seal assembly.
The flush pressure must be a minimum of 1 Bar (15 psi) greater

than the maximum discharge pressure created by, or the

maximum suction pressure applied to, the pump, whichever

is the greater.

Note: The limiting flush pressure in any

application is 13 bar (188 psig).

Note: The liquid supply connections to flushed seals are

made using the threaded ports on the sides of the seal

housings (two per seal, except CP10 & CP20 models,

which have common seal housings encompassing both

shaft seals). for models CP30 to CP50 inclusive, one

port on each housing should be used for flush ‘in’ and the

other for flush ‘out’. The pipe work should be arranged to

provide an independent flush to each seal.

- Before assembly or disassembly of the seals,

ensure pump is fully shutdown, refer to

section 3.5.

- Install O-ring (7.04) into the casing (3.01).
- Install rotary seal sleeves (7.15) onto shafts (5.01 and 5.02),

ensuring engagement of slots in rotary seal sleeves (7.15)

and drives pins (5.230

- Install O-ring (2.04 onto shaft (5.01 and 5.02).
Note: During installing of the rotors to shafts care must

be taken not to damage or unseat the O-ring seal when

inserting the rotor (2.01) into O-ring (7.04).
- To disassemble reverse the above procedure.

7.0 fLUSHED PRODUCT SEALS

AUXILIARy SERVICES

i) Terminology.

a) “Quench”

- To provide a liquid barrier that is not induced to flow

through the seal area by any external means.

b) “Flush”

- To provide a liquid barrier that is induced to flow

through the seal area by an external means.

ii) Quench or Flush Media

The media used for quenching or flushing a seal

area must be fully compatible with the pumped

media, and the relevant materials of construction

of the pump.
Special consideration must be given to the

temperature limitations of the media to ensure

that no hazards are created, e.g. risk of fire or

explosion.

6.3 O-RING SEAL fOR CP50 PUMP
6.3.1 CP50 O-RING SEAL ASSEMbLy

AND REMOVAL

figure 58

CP50 O-ring Seal

!

WARNING

WARNING

!

WARNING