SECTION TSM 630.4

ISSUE

D

PAGE 4 OF 10

DANGER !

All electrical power to the controller and

controlled circuits must be disconnected

before removing the controller from the front

panel or disconnecting other wiring.
Failure to follow these instructions may cause

an electrical shock and/or sparks that could

cause an explosion in class 1 div. 2 hazardous

locations.

Removing The Mounted Controller

From Its Case

Returning the Controller to its Case

1. From the face side of the controller, pull out the tabs on

each side until you hear it click.

1. Ensure that the orientation of the controller is correct and

slide it back into the housing. The controller is keyed so

it should slide easily back in to the case.

Do not force it.

Verify orientation again if it will not slide back into the case.

2. Using your thumbs push on either side of the controller

until both latches click.

2. Once the sides are released grab the unit above and

below the face with two hands and pull the unit out.

Pull out the tab on each

side until you hear it click.

Grab the unit above and below

the face and pull forward.

INSTALLATION

Controller

Assembly
1.
Make the panel cutout using the mounting template

dimensions shown in

Figure 1.

2. Insert the case assembly into the panel cutout.
3. While pressing the case assembly firmly against the panel,

slide the mounting collar over the back of the controller.

If the installation does not require a NEMA 4X (UL50, IP66)

seal, simply slide together until the gasket is compressed.

4. For a NEMA 4X (UL50, IP66) seal, alternately place and

push the blade of a screwdriver against each of the four

corners of the mounting collar assembly. Apply pressure

to the face of the controller while pushing with the

screwdriver.

Don’t be afraid to apply enough pressure to properly install

the controller. The seal system is compressed more by

mating the mounting collar tighter to the front panel. If

you can move the case assembly back and forth in the

cutout, you do not have a proper seal.

The tabs on each side of the mounting collar have teeth

that latch into the ridges on the sides of the controller.

Each tooth is staggered at a different depth from the front

so that only one of the tabs on each side is locked onto

the ridge at a time.
Note: There is a graduated measurement difference

between the upper and lower half of the display to

the panel. In order to meet the seal requirements

mentioned above, ensure that the distance from the

front of the top half of the display to the panel is

0.630 in. (16 mm) or less, and the distance from the

front of the bottom half and the panel is 0.525 in.

(13.3 mm) or less.

Slide the mounting collar over

the back of the controller.

!

Advertising