Operation, Key layout and functions, Warning – Viking Pump TSM630.4: K-QS 124E Controller User Manual

Page 8

Advertising
background image

SECTION TSM 630.4

ISSUE

D

PAGE 8 OF 10

OPERATION

1. Press and hold the Infinity Key for two seconds to bring up

the Home Page.

2. Use the Up and Down Arrow Keys to adjust the set point

temperature if necessary. The lower display of the Home

Page shows the set point temperature. The set point

temperature needs to be slightly higher than the melting

point and significantly lower than the flash point or boiling

point of the liquid being pumped.

WARNING !

Depending on the set point temperature at

startup, the controller may deliver power to

the heat cartridges and cause them to heat as

soon as the controller is turned on.

WARNING !

Setting the set point temperature higher than

necessary will not make the pump heat any

faster and will shorten the life of the heat

cartridges.

3. To make sure that the liquid within the pump is melted and

to avoid damage to the pump, do not start the pump until

the set point temperature has been reached. Depending

on your setup, there may be a ready light to indicate when

the set point has been reached. On the Home Page, the

upper display shows the process temperature, and the

lower display shows the set point temperature.

!

!

kEY LAYOUT AND FUNCTIONS

Upper Display
In the Home Page, displays the

process value, otherwise displays

the value of the parameter in the

lower display.

Temperature Units
Indicates whether the

temperature is displayed in

Fahrenheit or Celsius.

Zone Display
Indicates the

controller zone.

Percentage Units
Lights when the controller

is displaying values as a

percentage.

EZ key
Not Used

Output Activity
Number LEDs indicate activity

of outputs. A flashing light

indicates output activity.
#2 indicates when power

applied to heaters.

Lower Display
Indicates the set point

or output power value

during operation, or the

parameter whose value

appears in the upper

display.

Up and Down Arrow keys
In the Home Page, adjusts the

set point in the lower display.

In other pages, changes the

upper display to a higher or

lower value, or changes the

parameter selection.

Infinity key
Press to back up one level, or press and hold for two

seconds to return to the Home Page. From the Home

Page, you can clear alarms and errors if clearable.

Advance key
Advances through parameter prompts.

NOTE:
This controller has been pre-

programmed by Viking Pump

to lockout many functions

to simplify installation and

operation for customer specified

electric heat applications.

If advanced functionality is

required, the user should

source their own controller from

a qualified heat control vendor.