Keypad 10 line lock, Programming instructions (continued), Initial set-up procedures – SARGENT Keypad Cylindrical Locks User Manual

Page 15: All of the following procedures start with 99, Change master code

Advertising
background image

13

A7113E • 800-810-WIRE (9473) • www.sargentlock.com

Keypad 10 Line Lock

8

/1

4

/0

8

C

o

p

yr

ig

h

t

©

2

0

0

5

,2

0

0

7

,2

0

0

8

,S

A

R

G

EN

T

M

a

n

u

fa

c

tu

ri

n

g

,a

n

A

S

S

A

A

B

LO

Y

G

ro

u

p

c

o

m

p

a

n

y.

A

ll

ri

g

h

ts

re

se

rv

e

d

.

R

e

p

ro

d

u

c

ti

o

n

in

w

h

o

le

o

r

in

p

a

rt

w

it

h

o

u

t

th

e

e

xp

re

ss

w

ri

tt

e

n

p

e

rm

is

si

o

n

o

f

S

A

R

G

EN

T

M

a

n

u

fa

c

tu

ri

n

g

is

p

ro

h

ib

it

e

d

.

Programming Instructions (Continued)

6

This Keypad 10 Line Lock has 99 User Codes available for programming purposes.

• The Master Code is always User “01”. The Master Code assigns the Emergency and Supervisory Codes.

It is also used for programming. Users are deleted through the Master Programming Code only.

• The Emergency Code is always User “02”. The Emergency Code has an unlock time of 10 seconds.
• The Supervisory Code is always User “03”. The Supervisory Code allows temporary lockout of selected

users, changes duration of unlock time, requests infrared interrogation output, and may add additional
User Codes.

• The first User Code will be User “04” or higher. User numbers do not have to be used or entered

sequentially.

• User codes “98” and “99” have a factory-set unlock time of ten seconds. This allows a handicapped person

extra time which would not be required by other users.

To Begin Programming:

The Keypad 10 Line Lock is preset at the factory with Master Code “1234”. Entering 1234 * will unlock
the lock allowing the lever handle to retract the latchbolt.

Initial Set-Up Procedures:

• The following are typical procedures to follow when setting up your KP10G77 Keypad.
• If a mistake is made during any of procedures, depress the “*” several times until the yellow LED goes out.
• If no keystroke is made in a 30 sec. time frame, the programming up to that point will default and you will

have to start over.

All of the following procedures start with 99#.

If after the last “*” is depressed, the yellow LED does not go out, depress “*” once more.

Change Master Code:

• 1234* (Yellow LED Begins to Blink Slowly) This example uses the Factory Default Master Code
• 50# 1# 01# New Master Code* (Yellow LED Blinks Quickly)
• New Master Code* (Yellow LED Blinks Slowly) *(Yellow LED Goes Out)

To Enter the Emergency Code:

(Unlock Duration is Factory Set at 10 Sec)

• Master Code* (Yellow LED Begins to Blink Slowly)
• 50# 1# 02# Emergency Code* (Yellow LED Blinks Quickly)
• Emergency Code* (Yellow LED Blinks Slowly) * (Yellow LED Goes Out)"

To Enter the Supervisory Code:

• Master Code* (Yellow LED Begins to Blink Slowly)
• 50# 1# 03# Supervisory Code* (Yellow LED Blinks Quickly)
• Supervisory Code* (Yellow LED Blinks Slowly) *(Yellow LED Goes Out)

Advertising