Profile series v.g1 mortise lock – SARGENT Profile Series v.G1.5 Mortise Locks User Manual
Page 8

Non Fire Rated Exterior Doors-
Install Weather Conduit
(P/N 52-2847) as shown below
Outside of
door
6
800-810-WIRE (9473) • www.sargentlock.com • A7756A
Profile Series v.G1 Mortise Lock
Copyright © 2006, 2008, Sargent Manufacturing Company
, an A
SSA ABL
O
Y
Group company
. All rights reserved.
Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.
Inside of
door
(2) #12-24 x 1/2" long
flat head screw
for metal doors
(2) #12 x 1-1/4" long
flat head wood screw
for wood doors
Insert Lockbody in mortised cutout
Hold loosely in place with (2) lockbody screws
DO NOT COMPLETELY TIGHTEN SCREWS
AT THIS TIME
MUST feed
Connector
& Wires thru
non-cylinder
side.
Step #3 – Lockbody Installation
Step #4 – Attach Fire Stop Plate
Wires and connector go into the mortised area and out of the inside cylinder hole
Outside of
door
CL Of 1-1/2" Dia.
(2) Self tapping
screws #8 x 1/2"
long for wood
& metal doors
(2) 1/8" Dia. holes required
7"
8
1"
2
Slot
1
Fire stop plate
NOTE: Required for 12- fire rated doors.