STEP 7

Rotate and verify the set screw hole in both mounting plate assemblies

face the hinge and push both spindles into the latch assembly hubs.

Front Edge

of Door

Set screw hole on

lever bushing must

face the hinge

Mounting Plate

Assembly

spindle

STEP 8

Position the outside front onto the latch

assembly and secure with provided screws

X

STEP 9

Assemble the inside and outside collars by threading to the mounting plate with

provided tool
• Orient the bushing to collar as shown (65 function only)

STEP 10

Assemble the inside and outside

levers with provided set screw

(not shown)
• Test assembly
• Install Strike

Note:

Collars must lie flush against the door

Edge of Door

Dummy Trim Assembly Shown

Use assembly steps 2, 6, 9 & 10 for

dummy trim installation

Template for RDLU93 & RDLU94

2-3/4" Standard

2-3/8" (20-)

BACKSET

2X .250 ± .016 THRU

.900 ± .016

38" FROM

FINISHED FLOOR

SUGGESTED HEIGHT

1.250 MIN

6" MIN

3" MIN

OUTSIDE

OF DOOR

SUITABLE REINFORCEMENT IN

AREA SHOWN TO PREVENT

BOWING OF DOOR SURFACES

CL OF

BEVEL

2