SARGENT MPower 3000 User Manual

SARGENT Safety

Advertising
background image

MP3000 Door Operator
RF Kit

Kit RFR1

Instructions -

Page 1

RFR1
24VDC

Power Supply

6-32 x 1/4 “ Phillips
Round Head Screw
(Qty 4)

6-32 x 3/8 Standoff
(Qty 4)

RFR1 Kit instructions for installing a 433MHz Receiver in a MP3000 unit

Step 4. Connect (3) short splicing wires (provided) to the three

position terminal on the RFR1 Power Supply
Terminal 1 ----(Black wire)
Terminal 2 ----(White wire)
Terminal 3 ----(Green wire)

Use these wires
for splicing

Pull slack in wires to
this area for Tap
Connectors

Step 3. Mount power supply as

illustrated

Step 2. Note the wires that will be spliced into the 120VAC supply

Hot ------------ (Black wire)
Common ----- (White wire)
Earth Ground (Green wire)
Power supply will be mounted on stand offs over top of the

wires shown

Black

White

Green

Step 5. Use the three tap connectors (provided) to splice power

supply leads into units 120VAC power.
Splice Black to Black; White to White; and

.

Green to

Green

Step 1. Toggle circuit breaker to OFF position to terminate power

to unit before proceeding

A7872B

Step 6. Mount 433MHz Receiver to unit as shown using Velcro

strip provided

Use cable ties (provided) to secure the RF’s wiring
harness to the units existing wiring to insure RF’s wiring
will not come in contact with sprockets or chain

CAUTION

!

R

© SARGENT Manufacturing Company 2006

An ASSA ABLOY Group company