Final adjustment and regulating procedure – SARGENT 1431 Series Aluminum Closer User Manual

Page 2

Advertising
background image

1/8" HEX SOCKET

WRENCH

B

ACKCHECK

RANGE

D

ELAYED ACTION

RANGE

C

LOSING SPEED

RANGE

L

ATCHING SPEED

RANGE

DOOR WIDTH

1431 DOOR CLOSER

(INCHES)

24-30

TURN nut 1-3 CCW

30-36

FACTORY SET

36-42

TURN nut 1-3 CW

42-48

4-6 CW

ADJUSTING DOOR TO CLOSE DUE TO HIGH DRAFT CONDITIONS MAY EXCEED ADA
STANDARDS. CONSULT LOCAL ORDINANCES WHEN FIRE DOORS ARE INVOLVED.

SLIDE TRACK OVER ROLLER AND INSTALL END CAPS.

SECURE TRACK TO FRAME WITH SCREWS PROVIDED.
HOLDER/BUMPER OPTION END TOWARD HINGE

1431 POT/PHT

D

E

Copyright © SARGENT Manufacturing. All rights reserved.
Reproduction in whole or in part without the express written
permission of SARGENT Manufacturing is prohibited.

A7194E

2

FINAL ADJUSTMENT AND REGULATING PROCEDURE

Adjust Door speed, and Latching speed valves to achieve the desired closing time.

Recommend 6 seconds minimum from 90° to the closed position.

If Backcheck is required, adjust valve to achieve a slight cushioning effect. Auxiliary stop required.

If closer is equipped with Delayed Action, regulate valve to achieve the desired delay.

ADJUST POWER TO ALLOW DOOR TO CLOSE AND LATCH.
Adjust closing power to the minimum required to reliably close and latch door.
- If door is hard to open, decrease power slightly.
- If door does not latch, increase power as required.
- Use the chart as a starting point.
- Doors adjusted with high closing power to overcome

strong draft conditions may exceed ADA standards.