10°
Adjust Closing Speed Time to between 3 to 7 seconds
from 90°. Use of the door by handicapped, elderly or
small children may require greater closing time.
!
Valve Adjustments
Sweep
+
-
Latch
+
-
Backcheck
+
-
Caution:
Don't completely
close valve
!
5
4
2
3
Adjustment Chart
EXTERIOR
INTERIOR
Regular Arm
Top Jamb
Regular Arm
Top Jamb
Parallel Arm
Parallel Arm
FULL
360°
TURNS OF
5/16 POWER
ADJUSTMENT
WRENCH
8100/8300/8500
DOOR
TYPE
OF
INST.
*
32"
(0.85M)
36"
(0.90M)
42"
(1.00M)
48"
(1.20M)
5
8
11
13
7
10
13
16
7
10
13
16
9
12
15
18
20 FULL (360°) TURNS MAXIMUM AVAILABLE
*
MAXIMUM DOOR SIZE
Number of Turns Required
Closer is shipped set at mid range setting = 10 turns
The closing force is adjustable from a size 1 to a size 6, as
outlined in ANSI Standard A156.4. When these series of door
closers are installed and adjusted to conform to ADA reduced
opening force requirements (5 lbs max.) for interior doors, they
may not have adequate closing force to reliably close and latch
the door. Power adjustments charted on this page are
recommended where possible, to ensure proper door control.
By law the Americans with Disabilities
Act (ADA) may require that door
closer installation comply with
accessability guidelines.
!