Spring power adjust – SARGENT 1331 Series Aluminum Closer User Manual

Page 6

Advertising
background image

— 6 —

Copyright © 2013 Sargent Manufacturing Company, an ASSA ABLOY Group company.

All rights reserved. Reproduction in whole or in part without the express written

permission of Sargent Manufacturing is prohibited.

A8175A

63-8175-6000-999

CLOSED

70°

10°

Adjust Closing Speed Time to between 3 to 7 seconds
from 90°. Use of the door by handicapped, elderly or
small children may require greater closing time.

!

Valve Adjustments

Sweep

+

-

Latch

+

-

Backcheck

+

-

Caution:
Don't completely
close valve

!

5

4

2

3

Adjustment Chart

EXTERIOR

INTERIOR

Regular Arm

Top Jamb

Regular Arm

Top Jamb

Parallel Arm

Parallel Arm

FULL

360°

TURNS OF

5/16 POWER

ADJUSTMENT

WRENCH

8100/8300/8500

DOOR

TYPE

OF

INST.

*

32"

(0.85M)

36"

(0.90M)

42"

(1.00M)

48"

(1.20M)

5

8

11

13

7

10

13

16

7

10

13

16

9

12

15

18

20 FULL (360°) TURNS MAXIMUM AVAILABLE

*

MAXIMUM DOOR SIZE

Number of Turns Required

Closer is shipped set at mid range setting = 10 turns

The closing force is adjustable from a size 1 to a size 6, as
outlined in ANSI Standard A156.4. When these series of door
closers are installed and adjusted to conform to ADA reduced
opening force requirements (5 lbs max.) for interior doors, they
may not have adequate closing force to reliably close and latch
the door. Power adjustments charted on this page are
recommended where possible, to ensure proper door control.

By law the Americans with Disabilities
Act (ADA) may require that door
closer installation comply with
accessability guidelines.

!

Spring Power Adjust

+

-

1

Mfg.
Date: KU

KU

2 Cover
Screws