4299 WALL SWITCH

INSTALLATION INSTRUCTIONS

INSTALLATION (continued)

B. Installation

Reach Ranges

• If a clear floor space allows only a forward approach, the maximum high forward reach shall be 48”.
• The minimum low forward reach shall be 15”.

If the high forward reach is over an obstruction, the following conditions hall be met:

• Knee space below obstruction shall equal or exceed reach length required above the obstruction.
• If the obstruction is less than 20” deep, the maximum high forward reach shall be 48”.
• If the obstruction is 20-25” deep, the maximum high forward reach shall be 44”.
• If a clear floor space allows a parallel approach, the maximum high side reach shall be 54”.
• The minimum low side reach shall be 9”.

If the high side reach is over an obstruction, the following conditions shall be met:

• Obstruction shall be 34” maximum in height, 24” in depth, maximum high side reach shall be 46”.

Typical Wiring for Basic System

Pressing the button will momentarily release the lock. The lock will

remain unlocked as long as the push button is held depressed.

CONTROL SWITCH 4299

ELECTRIC LOCK,
EXIT DEVICE, or
ELECTROMAGNETIC LOCK

( - )

( + )

24VDC REG.
POWER
SUPPLY

1. Mount a single-gang outlet box to stud or other rigid structure.
2. To meet ADA requirements, the following must be observed: