A8148:A 11-16-12
Step 1: (Note: 657 Strike must be installed before
proceeding with 604 Rub Strip installation.)
Measure the distance between the front face of
the strike and the front face of the door frame.
Step 2: Using this measurement, cut the 604 Rub Strip
to the length needed.
Step 3: Drill and tap four #6-32 holes into the door
frame in the locations shown.
Step 4: Secure the 604 Rub Strip to the door frame
using the four #6-32 x ¼” screws provided.