SARGENT FM8700 Surface Vertical Rod Exit Device User Manual

Install top bolt and strike

Advertising
background image

1

A7827D 3-10-10

Copyright © 2006-2010, Sargent Manufacturing Company, an ASSA ABLOY Group
company. All rights reserved. Reproduction in whole or in part without the express
written permission of Sargent Manufacturing Company is prohibited.

TOOLS REQUIRED

• Power drill, drill bits #7, #16, #25, 3/32",

1/4", 11/32", 3/8", 25/64", and 3/4"

• Taps, #10-24, #12-24, 1/4"-20, 7/16"-20
• Hacksaw or power cutter
• Screwdrivers, Phillips #2, #3
• Allen wrenches, 1/8", 3/16", 5/16", 3/8"
• Level, Pencil, Tape Measure

Top rod

Chassis

Chassis cover

Top case

Bottom rod

Bottom case

End cap bracket

End cap

Push rail assembly

NOTE: THIS DEVICE IS ONE COMPONENT OF A SPECIFIC COMBINATION
OF HARDWARE REQUIRED FOR THIS OPENING TO MEET FEMA 361
REQUIREMENTS. FOLLOW ALL INSTALLATION STEPS AS DIRECTED,
IN SEQUENCE GIVEN.

NOTE: FOR 12-FM8700 SINGLE DOOR APPLICATION, (4) THERMAL PINS
ARE REQUIRED. SEE TEMPLATE 4628, PG. 4.

Rail Lengths & Cutting Instructions, Pg.4.

THIS EXIT DEVICE IS HANDED

Right hand
reverse bevel

OUT

1

Finished floor

“A”

“B”

41"

Inside

face of

door

5/8"

Max

1. MARK VERTICAL REFERENCE

LINE A.
A is CENTERLINE for chassis,
top and bottom cases

2. MARK HORIZONTAL REFERENCE

LINE B at
41" above finished floor.
B is CENTERLINE for
chassis and rail

3. TAPE TOP CASE AND CHASSIS

TEMPLATES TO DOOR (PACKED
WITH DEVICE)

PREPARE CUT-OUT IN FRAME FOR
659 TOP BOLT / STRIKE
Use 11/64" drill, 12-24 tap, #3 Phillips screwdriver.

INSTALL 659 TOP BOLT / STRIKE
Transfer vertical centerline to door frame. With
the door closed, align INTERLOCKING SHIM
with 659 TOP BOLT/STRIKE and place on vertical
reference line. Mark and drill 4 mounting holes
using 11/64" drill and 12-24 tap.

MOUNT 659 TOP BOLT/STRIKE, (4)
#12-24 x 3/4" PH.FL.HD.Mach. Screws
NOTE: ALL FOUR FASTENERS
REQUIRED. DO NOT TIGHTEN UNTIL STEP 4

Frame Cutout

Top Bolt

#659 Top Plate

Top bolt assembly in
frame, cut-away view

2

INSTALL TOP BOLT AND STRIKE

INSTALLATION INSTRUCTIONS
FM8700, 12-FM8700 Surface Vertical Rod Exit Device

FOR INSTALLATION ASSISTANCE, CALL SARGENT AT 1-800-727-5477 • www.sargentlock.com

U.S. Patent No. 268,003

Canadian Patent No. RD 1981

Left hand

reverse bevel

Interlocking
shim

Advertising