1. Ensure power to device is disconnected.
2. Carefully disconnect all connectors (Fig. 1).
3. Remove insert assembly from rail mounting assembly.
4. Loosen set screw by turning counter-clockwise using
5/64” allen wrench.
5. Extract and slide cylinder through spring and collar.

Cylinder Orientation

Top View with cylinder removed

Set Screw

Collar

Spring

Cylinder with Key

See illustration on circuit board for correct orientation of
cylinder/cam when installing.
Note that proper position of cam allows for removal of key.

Insert Assembly

When replacing cylinder, slide cylinder through spring
then collar, taking care to orient cylinder as shown.

Bottom of Cylinder

Cylinder Cam

Illustration (on circuit board)

1

Replacement Instructions

Top of Cylinder

Prefix

Part
Number

Description

PCB Module Assembly Replacement

59-

52-4837

Standard

59- BC- 52-4838

BOCA (30 seconds)

57-

52-4830

Standard

57- BC- 52-4831

BOCA (30 seconds)

Connector Locations

Fig. 1

NOTE: Use caution when
removing insert assembly
to avoid damaging the rail
harness connected to the
PCB module assembly.

1 1-800-810-WIRE • www.sargentlock.com • A8184A

Copyright © 2013, Sargen

t Manufacturing Company

, an A

SS

A AB

LO

Y G

roup company

. All right

s reser

ved

.

Reproductions in whole or in par

t without express writ

ten permission of Sargen

t Manufacturing Company is prohibited

.

10/31/13

57/59- Prefix 80 Series Exit Device

PCB Module Assembly

Replacement Instructions

Advertising
This manual is related to the following products: