2) Calculate Bottom Pins and Master Splits

Find correct size for Bottom and Master Splits from operating key's list

(a)* * * * * * BOTTOM PINS * * * * * * * *

2

1

2

1

2

2

(Smallest number in each chamber)

(b)* * * * * * MASTER SPLITS * * * * * * *

2

8

2

2

4

8

(Difference in smallest and largest number in each chamber)

3) Calculate Value of Control Splits

3.3 CONTROL KEY BITTING

4

9

6

5

6

0

(3.1) A number 8 appears on this line in positions 3 and 4

-

-

8

8

-

-

(3.2) Insert bitting of positions 3 and 4 of control key.

and add to number 8’s in positions 3 and 4

+6

+5

3.3 CONTROL PIN FACTOR

=

14

13

(3.4) Subtract largest number in positions 3 and 4

from list of operating keys from control pin factor

-4

-3

(c)* * * * * * CONTROL SPLITS * * * * * * * *

=

10

10

4) Calculate Top or Driver Pin

(Total Stack Value)

15

15

20

20

15

15

(4.1) Add value of: (a) Bottom Pins, + (b) Master Splits

+ (c) Control Splits).Enter total here.

4

9

14

13

6

10

(4.2) Subtract total from TOTAL STACK VALUE above.

(d) (4.3) Enter values on this line. DRIVER SPLITS (Master Splits)

11

6

6

7

9

5

5) Pinning Assembly Matrix

Example of pinning matrix for above key bittings.

Transfer Values labeled

(d) Driver Splits

11

6

6

7

9

5

(a), (b), (c), (d) from items

(c) Control Splits

-

-

10

10

-

-

2, 3, and 4 above.

(b) Master Splits

2

8

2

2

4

8

(a) Bottom Pins

2

1

2

1

2

2

Stack Total

15

15

20

20

15

15

Limits

SARGENT

®

LFIC (Removable Core) Cylinders

Template 6300 & 11-6300 & 10-6300 LFIC (Removable Core) Cylinder

The following is an example showing how to select the pin segments for each chamber of
the SARGENT 6300 series LFIC (removable core). Use this as a template for calculating
the correct pin loads.

I____|____|____|____|____|____|

|____|____|____|____|____|____|

|____|____|____|____|____|____|

|____|____|____|____|____|____|

|____|____|____|____|____|____|

|____|____|____|____|____|____|

|____|____|____|____|____|____|

|____|____|____|____|____|____|

|____|____|____|____|____|____|

|____|____|____|____|____|____|

|____|____|____|____|____|____|

|____|____|____|____|____|____|
|____|____|____|____|____|____|

|____|____|____|____|____|____|

|____|____|____|____|____|____|

|____|____|____|____|____|____|

1) List of Operating Keys

Sample

Sample

KEY SYMBOLS

BITTINGS

List Day Changes/MK’s GM’s etc

.

GM “A”

4 9

4

1

6

0

|____|____|____|____|____|____| |____|____|____|____|____|____|

Do Not list bitting of

MK “AA”

4 9

2

3

6

0

|____|____|____|____|____|____| |____|____|____|____|____|____|

the Control key in this area.

CK “AA1”

2 1

2

3

2

2

|____|____|____|____|____|____| |____|____|____|____|____|____|

-

8

15

15

20

20

15

15

8

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

Sample

Copyright © 2009, 2011, Sargent Manufacturing Company, an ASSA ABLOY
Group company. All rights reserved. Reproduction in whole or in part
without the express written permission of Sargent Manufacturing
Company is prohibited.

A6409K 12/01/11

Advertising
This manual is related to the following products: