SARGENT 7800 Knob Locks User Manual

Page 2

Advertising
background image

Inside of

door

Outside of

door

G

F

E

D

D

C

A

B

Inside of

door

(4) Slide cylinder (A) through spring (B) &

collar (C) (or escutcheon) and thread
into lock until cylinder face is flush
with collar (C) (or escutcheon edge).
The key slightly pulled out of cylinder
will help to thread the cylinder

Note: SARGENT logo must be
horizontal & on the top portion
of the cylinder

(5) By hand with # 2 Phillips screwdriver,

tighten cylinder clamp screw

(6) Secure lock in door with two

wood screws #12 x 1-1/4" or
machine screws #12-24 x 1/2" (D)

(7) Slide spindle (E) into lockbody hub

(8) Slide adapter & plate assembly (F)

over spindle & secure with two
#8-32 screws (G)

(3) Slide outside lever & rose

assembly (or lever & escutcheon
assembly) through the door and
lock body

(2) Slide lock in door

(1) Important: Check template A7057 to prep door

for function holes, size & location. Verify strike
location according to template. Clean door
pocket and verify hand of lock

RH Door Shown

Outside of

door

Cylinder Clamp
Screw

Note: Keep door open
while installing lock

Note: If installing trim one side,
see separate instruction sheet

R/C & I/C cylinder cores require Control key
(stamped “C”) to install. Must request separately.
If 1 bitted - specify 11311 cut.

2

INSTALLATION INSTRUCTIONS
7800/8200 Series Mortise Locks (Except PT Trim & FE Trim)
See Particular Trim Section for Your Lock

FOR INSTALLATION ASSISTANCE CALL SARGENT AT 1-800-727-5477 • www.sargentlock.com

Copyright © 2009, Sargent Manufacturing Company, an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written
permission of Sargent Manufacturing Company is prohibited.

A7034G

Advertising
This manual is related to the following products: