Fluids and lubricants, Maintenance procedures, Visual inspection – Wheatheart X Series 13 Augers User Manual

Page 100: Fluids and lubricants 7.3. maintenance procedures, Refer to section 7.3

Advertising
background image

7. M

AINTENANCE

W

HEATHEART

- X13 S

ERIES

A

UGERS

7.2. F

LUIDS

AND

L

UBRICANTS

X1374, X1384, X1394

100

30787 R1

7.2. FLUIDS AND LUBRICANTS

G

EAR

O

IL

Use SAE approved 90W or equivalent gear oil.

G

REASE

Use SAE multi-purpose high-temperature grease with extreme pressure (EP)
performance or SAE multi-purpose lithium-based grease.

7.3. MAINTENANCE PROCEDURES

7.3.1. V

ISUAL

I

NSPECTION

Before beginning visual inspection, check auger wheels and ensure that all
operators are aware of safety procedures.

When inspecting, look for possible defects and for the following:

• Be sure all guards are in place, functioning, and not damaged.
• Make sure access, service, and cleanout covers are in place and secure.
• Check that all hardware is in place and secure.
• Inspect hydraulic hoses and fittings for leaks and wear. Fix or replace

where necessary.

• Inspect around the machine for evidence of hydraulic leaks.
• Examine flighting for damage or unusual wear.
• Inspect the truss cables for proper tension and possible damage such as

fraying, kinking, or unwinding.

• Inspect hopper winch cable for fraying, kinking, unwinding, or other possi-

ble damage.

• Examine tires for gashes, uneven wear, or loss of air pressure.
• Be sure all safety decals are in place and legible.
• Check the PTO shield & replace if damaged.

Advertising