Auger tube truss assembly, X130-74 auger tube truss assembly – Wheatheart X Series 13 Augers User Manual

Page 35

Advertising
background image

W

HEATHEART

- X13 S

ERIES

A

UGERS

3. A

SSEMBLY

X1374, X1384, X1394

3.10. A

UGER

T

UBE

T

RUSS

A

SSEMBLY

30787 R1

35

3.10. AUGER TUBE TRUSS ASSEMBLY

• X130-74 augers use a double cable truss on the top of the auger tube “X130-

74 Auger Tube Truss Assembly” on page 35).

• X130-84 and X130-94 augers use a combination of rigid tube trussing on top

of the auger tube and cable trussing on the sides of the auger tube (see
“X130-84/X130-94 Auger Tube Truss Assembly” on page 40).

3.10.1. X130-74 A

UGER

T

UBE

T

RUSS

A

SSEMBLY

I

NSTALL

THE

X130-74 C

ABLE

B

RIDGES

See Table 3.7. for a list of parts required to install the X130-74 cable bridges.
See Figure 3.12 for a detailed diagram.

1. Fasten the three truss towers to the provided brackets (welded to the

appropriate tube sections):
a. Position the high truss tower in the centre position, and position the low

truss towers toward the spout and intake ends.

b. Use two 7/16” x 1-1/4” GR8 bolts and 7/16” locknuts to fasten each cable

bridge in place.

2. Install the truss cable attach bracket as shown in the diagram, using two

7/16” x 1-1/4” GR8 bolts and 7/16” locknuts.

Table 3.7. Parts Required, Installing X130-74 Cable Bridges

Part Number

Description

Amount

20017

High truss tower

1

18988WH

Low truss towers

2

20105

Truss cable attach bracket

1

18698

7/16” x 1-1/4” GR8 bolts

8

17593

7/16” locknut

8

Advertising