Lowering & completion – Wheatheart X Series 13 Augers User Manual

Page 97

Advertising
background image

W

HEATHEART

- X13 S

ERIES

A

UGERS

6. O

PERATION

X1374, X1384, X1394

6.3. O

PERATING

P

ROCEDURES

30787 R1

97

6.3.6. L

OWERING

& C

OMPLETION

1. Run the unit to clean out the majority of the grain from the main auger tube,

boot, and hopper.

2. Turn off the tractor, and lock out the tractor power source (Refer to page 89

for procedure).

3. Disconnect the PTO driveline, and raise the intake hopper off the ground.
4. Remove all supports and chocks.
5. Move

auger

away from the bin, and ensure that there is nothing under the

auger that would make contact when the auger tube is lowered.

6. Open the main auger tube lift valve on the boot.
7. Open the tractor supply valve for the auger, and feather between on and off

to make sure that the auger tube lowers slowly.

8. If necessary, open the clean-out door on the boot and manually clean out

grain using a piece of wood, vacuum cleaner, or other tool. Do not use your
hands. Replace the clean-out cover.

9. Lift the intake feed hopper into transport position, and secure it with the

safety chain.