7. M

AINTENANCE

X1374, X1384, X1394

7.1. M

AINTENANCE

I

NTERVALS

30787 R1

99

7. Maintenance

7.1. MAINTENANCE INTERVALS

For details of service, refer to Section 7.3.

NOTICE

Do not modify equipment.

Unauthorized modification may impair the function or safety
of the equipment, could affect the life of the equipment, and
will void your warranty.

WARNING Before continuing, ensure you have read and understand the relevant information
in the safety section. Safety information is provided to help prevent serious injury, death, or
property damage.

SECTION

DAILY
(8000
BU)

PERIODICALLY
(40,000 BU)

BEFORE
STORAGE

AFTER
STORAGE

3-5 YEARS
(DEPENDING
ON USE)

VISUALLY INSPECT THE UNIT

7.3.1.

Y

-

Y

-

-

INSPECT HYDRAULIC HOSE
AND COUPLER

7.3.2.

Y

-

-

-

-

GREASE MACHINE

7.3.3.

Y

-

Y

-

-

INSPECT HOPPER LIFT
CABLE

7.3.4.

-

Y

-

-

-

SERVICE WINCH AND
PULLEYS

7.3.5.

-

Y

-

-

-

SERVICE SWING TUBE
COUPLER CHAIN

7.3.6.

-

Y

-

-

-

SERVICE BOOT AND HOPPER
CHAIN DRIVE

7.3.7.

-

Y

-

-

-

CHECK GEARBOX OIL LEVEL

7.3.8.

-

Y

-

-

-

CLEAN MACHINE

7.3.9.

-

-

Y

-

-

CHECK TIRE PRESSURE

7.3.10.

-

-

Y

Y

-

REPACK WHEEL BEARINGS

7.3.11.

-

-

-

-

Y

TIGHTEN WHEEL BOLTS

7.3.12.

-

-

-

Y

-

SERVICE TRUSS CABLES

7.3.13.

-

-

-

Y

-

CHANGE GEARBOX OIL

7.3.15.

-

-

-

-

Y