Flow: ground drive row-hopper air-pro, Dry fertilizer planters – Great Plains PTO Kits 2-3-Section User Manual

Page 21

Advertising
background image

Great Plains Manufacturing, Inc.

Table of Contents

Index

PTO Operation

17

2014-09-10

Table of Contents

Index

411-015M

Flow: Ground Drive Row-Hopper Air-Pro

®

Dry Fertilizer Planters

On model 1625AHD planters, the PTO pump drives a
single fan which delivers dry fertilizer and pressurizes the
seed meters. Setting and balancing pressures is a
manual operation. The seed monitor reports fan rpm.

Review the air system overview, fan operation, and
butterfly valve adjustment in the 411-020M Operator
manual before adjusting for PTO operation.

1.

Look up the recommended meter pressurization for
the intended crop (see Seed Rate manual). Make a
note of the previous or factory settings of all butterfly
valves. Load seed in hoppers and meters. Meters
must be full to inlet shutters for valid readings.

Refer to Figure 13
2.

Close the manifold outlet butterfly valve
(set to 90

°). If the wing butterfly valves have been

previously adjusted for balance, leave them
undisturbed, otherwise set them full open (0

°).

3.

• Check that tractor is in Park or Neutral.
• Check parking brake set.
• Set the tractor PTO controls for

1000 rpm gearing (if multi-speed) and
clockwise rotation (if bidirectional).

• Start tractor engine and set throttle to idle.
• Engage the PTO.
• Bring the tractor engine and PTO up to intended

field rpms.

Entanglement and Crushing Hazard:
Use extreme caution in the hitch area when the PTO is
operating.

Refer to Figure 12
4.

At the flow control valve, turn the lock disc
counter-clockwise to release the knob

. Slowly

turn the knob counter-clockwise to start the fan.
Bring the fan speed up until the Air-Pro

®

gauge

displays the suggested pressure for this crop.
Secure the lock disc.

5.

Raise the planter. Turn each meter ground drive
wheel (2 or 3 per planter) forward several turns, until
all exposed cells in all seed disks contain seed.

6.

As necessary, readjust manifold outlet butterfly
valve

to achieve recommended pressure on the

Air-Pro

®

gauge

.

7.

Re-check both pressures in the field, with material
flowing at desired rates. Adjust fan speed to stay
within 35 to 45 inches on the fan manifold gauge

.

Adjust the manifold outlet butterfly valve

to the

suggested pressure for the seed.

Figure 12:

Flow Control Valve (1625AHL)

36339
29842

1

2

4

0

10

30

20

40

50

858-193C

3

5

Figure 13

Fertilizer Manifold Butterfly Valve

36134

858-208C

5

1

2

4

5

4

3

5

Advertising