55

2014-09-10

Table of Contents

Index

411-015M

401-936A Hose Diagram

Hydraulic

Connections

Call-

out

Part

Hose Description

Comments

Fan Pressure hose
from hitch

,

Existing Hose

Remove hose handles. Disconnect from fan. Reconnect
hitch end to PTO pump outlet. Reconnect rear end to
flow control valve port P.

Fan Case Drain
hose

Existing Hose

Remove QD fittings at hitch end. Connect hitch end to
reservoir case drain inlet.

Fan Return hose
from hitch

,

Existing Hose

Remove hose handles. Disconnect from fan. Reconnect
hitch end to reservoir inlet. Reconnect rear end to cooler
outlet.

Fan motor loop

Existing Hose

Left undisturbed.

Cooler Inlet hose

841-196C

HH1/2R2 024 3/4FJIC

Connects flow control valve port T to cooler inlet.

PTO Pump supply
hose

841-920C

HH1 1/4R4 070 1 5/8FJIC

Connects reservoir outlet to PTO pump inlet.

Fan Return hose

841-517C

HH1/2R2 054 3/4FJIC

Connects fan outlet to flow control valve port T.

Fan Supply hose

841-517C

HH1/2R2 054 3/4FJIC

Connects flow control valve port M to fan inlet.

A

B

C

D

E

L

263

282

273

273