Great Plains PTO Kits 2-3-Section User Manual
Page 59
Great Plains Manufacturing, Inc.
Appendix A - Installation
55
2014-09-10
411-015M
Hydraulic
Connections
Call-
out
Part
Hose Description
Comments
Fan Pressure hose
from hitch
,
Existing Hose
Remove hose handles. Disconnect from fan. Reconnect
hitch end to PTO pump outlet. Reconnect rear end to
flow control valve port P.
Fan Case Drain
hose
Existing Hose
Remove QD fittings at hitch end. Connect hitch end to
reservoir case drain inlet.
Fan Return hose
from hitch
,
Existing Hose
Remove hose handles. Disconnect from fan. Reconnect
hitch end to reservoir inlet. Reconnect rear end to cooler
outlet.
Fan motor loop
Existing Hose
Left undisturbed.
Cooler Inlet hose
841-196C
HH1/2R2 024 3/4FJIC
Connects flow control valve port T to cooler inlet.
PTO Pump supply
hose
841-920C
HH1 1/4R4 070 1 5/8FJIC
Connects reservoir outlet to PTO pump inlet.
Fan Return hose
841-517C
HH1/2R2 054 3/4FJIC
Connects fan outlet to flow control valve port T.
Fan Supply hose
841-517C
HH1/2R2 054 3/4FJIC
Connects flow control valve port M to fan inlet.
A
B
C
D
E
L
263
282
273
273