Great Plains PTO Kits 2-3-Section User Manual

Page 83

Advertising
background image

Great Plains Manufacturing, Inc.

Table of Contents

Index

Appendix A - Installation

79

2014-09-10

Table of Contents

Index

411-015M

411-014A Hose Diagram

Hydraulic

Connections

Call-

out

Part

Hose Description

Comments

Fans Pressure hose
from hitch

,

Existing Hose

Remove hose handles. Disconnect from fan

.

Reconnect hitch end to PTO pump outlet. Reconnect fan
end to flow control valve edge Port P

Fans Case Drain
hose

Existing Hose

Remove QD fittings at hitch end. Connect hitch end to
reservoir case drain inlet.

Fans Return hose
from hitch

,

Existing Hose

Remove hose handles. Disconnect from fan

.

Reconnect hitch end to reservoir inlet. Reconnect rear
end to new hose

from cooler

outlet.

Drive Pressure
hose from hitch

Existing hoses

Disconnect

at filter elbow. Hose is not reused, and is

capped with plug

.

Filter to
Proportional Valve

Existing hose left in place

Drive Motor Press.

Existing hose

Disconnect at existing proportional valve outlet elbow.
Reconnect at new tee

.

Drive Return hose
to hitch

Existing hoses

Disconnect

at filter elbow. Hose is not reused, and is

capped with plug

.

Fan Loop

Existing hose

Disconnect at existing tee

. Reconnect at new

cross

.

Fan Loop

Existing hose left in place

Forward Fan

is a re-connection.

Fan-to-Fan Press.

Existing hose left in place

Fan-to-Fan Return

Existing hose left in place

Fan-to-Fan Drain

Existing hose left in place

Fan Return Tee

811-077C

TE 3/4MORB 3/4MJIC 3/4MJIC

Remove. Not reused. Replace with new cross

.

Proportional Valve
Outlet tee

811-073C

TE 3/4MJIC 3/4MJIC 3/4FJIC

Add to existing elbow at proportional valve.

Sense Adaptor

811-146C

AD 3/4FJIC 9/16MJIC

Add to new tee

.

Fan Return Cross

811-147C

CR 3/4MJIC

Replace existing tee

.

Fan Return to
Cooler hose

811-268C

HH1/2R2 048 3/4FJIC

Connect the new cross

at the fan to the cooler

inlet.

Flow Control Return
hose

811-268C

HH1/2R2 048 3/4FJIC

Connect flow control valve Port T to new cross

at

fan

.

Fans Supply hose

811-340C

HH1/2R2 030 3/4FJIC

Connect flow control valve Port M to the existing tee at
fan motor

inlet.

Hose plugs

811-341C

PL 3/4MJIC

Cap drive ends of hoses

and

with plugs

.

Load Sense hose

841-477C

HH1/4R2 140 9/16FJIC

Connect between sense adaptor

and flow control

valve Port LS.

Cooler Outlet hose

841-506C

HH1/2R2 030 3/4MJIC
3/4FJIC

Connect cooler

outlet to existing fan return hose

.

Hydraulic Drive
Motor Return hose

841-556C

HH1/2R2 144 3/4FJIC

Connect the motor check valve to flow control valve
Port T.

Hydraulic Drive
Supply hose

841-556C

HH1/2R2 144 3/4FJIC

Connect flow control valve face Port P to filter inlet.

Pump Supply hose

841-956C

HH1 1/2R4 070 1 7/8FJIC

Connect the reservoir outlet to the pump inlet.

A

B

1

C

D

E

1

272

2

F

F

247

J

K

230

G

G

247

1

L 1

41

235

2

L 2

L 1

X

Y

Z

40

235

230

234

230

235

41

243

235

1

243

235

1

246

1

247

F

G

247

271

234

272

2

E

275

275

285

Advertising