38

2- & 3-Section YP PTO Pumps

Table of Contents

Index

Great Plains Manufacturing, Inc.

411-015M

Table of Contents

Index

2014-09-10

8in: Modify Fan Cage

Refer to Figure 43
63. Prepare an exit opening in the fan cage for the

cooler hoses. The hole needs to be:

Note: If an existing rpm sensor lead hole is present, and

at a suitable location, enlarge it for hose use.

8in: Install Cooler
64. Route the cooler hoses through the hole prepared

at step 63.

Refer to Figure 44
65. With the elbows toward the cooler shroud, position

the cooler

on the threaded studs of the cooler

shroud. Secure with 4 whiz nuts:

803-043C NUT HEX WHIZ 5/16-18 PLT

8in: Install Screen Extension
66. Select one new:

421-615D CRARY 8IN FAN SCREEN EXT

and eight saved screws originally used to secure
the screen cap to the screen. Secure the extension
to the screen using the saved screws.

8in: Install Screen Cap
67. Select the saved screen cap

and eight new:

802-800C HWH #12-14X3/4

Secure the cap to the screen extension by creating
new holes from the face of the screen.

• located at bottom center of the fan cage,

• on the center-line of the MJIC elbow ports,

• wide enough for a 3/4 FJIC hose fitting, about:

3.2 cm (1

1

4

inches)

a

• long enough for one hose diameter plus one

3/4 FJIC or 7/8 FJIC hose fitting, about
5.7 cm (2

1

4

inches)

a

total, and

• have a smooth edge. Making cuts (- - -) as

shown, and folding back the cage edges, to the
inside, provides an adequately smooth edge.

a. For assembly 401-143L, with 7/8 JIC hose ends, use

3.8 cm (1

1

2

inches) wide, 6.4 cm (2

1

2

inches) long

Figure 43:

8in: Hose Opening in Cage

210

223

190

205

2

Figure 44:

8 in. Fan Cooler Install

36377

223

210

190

2

205

Advertising