401-647Q

Connect Seed Hose Rack

Refer to Figure 51
For shipping, the seed tube hoses and rack (

or

)

that interconnect the air box and mainframe are strapped
to the walkboard. The seed tubes/rack need to be
dismounted and connected between the air box manifold
and the inner ends of the wing tubes.

Refer to Figure 50
78. Dismount the rack assembly from walkboard. It may

have a tag with the part number of the tube rack:

401-367K SEED TUBE RACK ASSY REAR 16

401-368K SEED TUBE RACK ASSY REAR 12

79. Identify rack orientation:

Ends: The hose lengths and mounting hardware are
different for each end of the rack. The end with the
longer hoses connects to the wing tubes. The end
with the shorter hoses connects to the air box. The
air box end also has pivot holes

in the frame.

Bottom: At the front (wing) end of the rack, the
bottom side frame has a short rail

on each side.

Refer to Figure 51
80. Note the idler spools

on each side of the inner

rear portion of the parallel arm brackets. The
forward end of the rack rests on these and is free to
slide during vertical movement of planter
components.

Refer to Figure 52
The rear ends of the outside tubes of the seed tube rack
have large holes

to accept a pivot sleeve for mounting.

Figure 50

Seed Tube Rack, Dismounted

29944

15

16

Air Box

Wings

2

1

15

16

15
16

Figure 51

Seed Tube Rack, Below Forward

29170

3

3

2

2

1

2

3

Figure 52

Rear Rack Pivot Hole

25379

1

1

Advertising