Install Gray Module Harness

The gray (input) module harness

is used in

configurations that take ISObus steering data, or native
tractor steering sensor data. It is not used with the Great
Plains linear sensor.

Not all of the leads are connected, and only two are
connected at this step.

Refer to Figure 85, and Figure 86
67. From the harness set:

833-547C HARNESS CANBUS STEERING MODULE

select the cable

with the Gray 12-pin Deutsch

connector.

Plug the Gray 12-pin Deutsch

lead into the

Gray input port receptacle

of the sensor

module

.

Connect the power input lead

to the switch box

power output lead

.

Continue at one of:

• If using native CANbus steering data, continue at

ISObus Compatible Connection” on page 53.

• If using the tractor’s existing (native) steering sensor,

continue at “Install Harness for Native Steering
Sensor
” on page 54.

Figure 85

Gray Module Harness

Signal / Power IN

31833

Lead

Function

9-pin (2 used): CANbus from tractor
ISO 11786 port (if used)

12-pin: data to sensor module input

3-pin (2 used): power from console

3-pin: input from tractor wheel angle sensor
harness

,

or

(if used)

74G

74c

74G

71i

74p

70p

74r

72r

73r

75r

74r

74c

74p

74G

74G

74

74G

74G

71i

71

74p

70p

Figure 86

Switchbox

, Module

,

Gray Module Harness

31840

70

71

74G

70

71

70p

74p

74G

71i

Advertising