ECU does not
power up
(no lights on
switch box)

Fuse blown

Check fuse, located at + battery terminal. If blown, check
for underlying problem before using system:
1.

Set STEER switch off on console.

2.

Disconnect harness to ECU
(ECU has standby power, even with console off).

3.

Replace fuse.

4.

Switch on console - check fuse.
If OK, switch off console and continue.

5.

Connect ECU harness. Check fuse. If OK, continue.

6.

Switch on console and check fuse.

Power input disconnected or
damaged.

Check voltage at 70-pin ECU plug, with console on:
Pins 1 and 2, then Pins 2 and 3

Low battery voltage

Check tractor voltage. Must be between 10 and 16Vdc.

Steering
doesn’t match
tractor

Calibration needed

Perform a steering calibration (page 59). If calibration does
not solve the problem, check for damaged sensor.

No caster
float in
transport

No radar signal (seen by ECU as
0 mph)

Check radar Y-cable connection and radar function

Disengage speed not set to proper
value in ECU setup

Contact Great Plains support. If the ECU firmware was
recently updated, there may be other incorrect settings.

Steering
reversed

Sensor installed on incorrect tractor
side or incorrect location on axle

Re-install sensor at location specified in Pre-Delivery
manual 401-647Q.

ST1 and ST2 connections reversed
at manifold valve

Check entire hydraulic system against diagrams in Parts
manual. Correct connections as necessary. If the
mis-connection was not the result of local maintenance,
report problem to dealer or Great Plains.

Hoses to steering cylinders reversed
at left cylinder

Check entire hydraulic system against diagrams in Parts
manual. Correct connections as necessary. If the
mis-connection was not the result of local maintenance,
report problem to dealer or Great Plains.

Harness connections reversed at
valve coils

Swap connections at ST1 and ST2. If the mis-connection
was not the result of local maintenance, report problem to
dealer or Great Plains.

Steering Troubleshooting (other than flash error codes)

Problem

Cause

Solution