195-440M

To change the bolts (to high pressure):

1.

Have a jack at hand.

2.

Loosen the nuts on all the top bolts

.

3.

Lower the opener sub-frames.

4.

Put the tractor hydraulic circuit for the openers in
float.

5.

Place jack under an opener tool bar at an arm.

6.

Lift the tool bar until the bolt is free.

7.

Remove the bolt.

8.

Repeat step 5 through step 7 the other arm of the
subframe.

9.

Raise the jack until the top holes are aligned.

10. Insert the bolt in the top hole

and spin on a nut.

11. Repeat step 5 through step 10 for each sub-frame.

12. Tighten all nuts.

13. Changing from high to low is similar, except lower the

jack at step 6 and reverse the bolt movement.

Hydraulic Down-Force

Pounds of Force at Opener Disks

Gauge

Setting

6 inch

rows

7

1

2

inch

rows

10 inch

rows

200 PSI

83

86

92

300 PSI

90

95

102

400 PSI

97

103

113

500 PSI

103

111

124

600 PSI

110

119

135

700 PSI

117

128

146

800 PSI

123

136

157

900 PSI

130

144

167

1000 PSI

137

152

178

1100 PSI

143

161

189

1200 PSI

150

169

200

1300 PSI

157

177

211

1400 PSI

163

185

222

1500 PSI

170

194

233

1600 PSI

176

202

244

1700 PSI

183

210

254

1800 PSI

190

218

264