Operating instructions, Tractor hookup – Great Plains YP1625 Operator Manual User Manual
Page 75
7/12/2005
401-182M
73
Veris Drive Operating Instructions
Operating Instructions
Drive Operational Requirements:
Hydraulic System:
• Closed center, pressure compensated or
load sensed systems only
• Drive will not operate on open-centered hy-
draulic systems
Minimum Hyd. Pressure: 2250 psi
Maximum Hyd. Pressure: 3000 psi
Maximum Required Flow: 13 gpm
Electrical System:
• Voltage:
12 volt DC
• Amperage:
4 amperes
Tractor Hookup
Hydraulics:
1.
Connect pressure hose (P) to retraction outlet
2.
Connect motor return hose (T) to motor return
port (if available) or to extension outlet.
3.
Set flow rate at maximum required flow of 13
gpm.
4.
If tractor is equipped with electro-hydraulic
valves, set timer to “constant” flow.
Electrical:
1.
Power must be connected directly to the bat-
tery. Make sure that eyelets are properly con-
nected (red to positive, black to negative).
Connect female socket to power port adapter.