Operating instructions, Tractor hookup – Great Plains YP1625 Operator Manual User Manual

Page 75

Advertising
background image

7/12/2005

401-182M

73

Veris Drive Operating Instructions

Operating Instructions

Drive Operational Requirements:

Hydraulic System:

Closed center, pressure compensated or

load sensed systems only

Drive will not operate on open-centered hy-

draulic systems

Minimum Hyd. Pressure: 2250 psi

Maximum Hyd. Pressure: 3000 psi

Maximum Required Flow: 13 gpm

Electrical System:

Voltage:

12 volt DC

Amperage:

4 amperes

Tractor Hookup

Hydraulics:

1.

Connect pressure hose (P) to retraction outlet

2.

Connect motor return hose (T) to motor return
port (if available) or to extension outlet.

3.

Set flow rate at maximum required flow of 13
gpm.

4.

If tractor is equipped with electro-hydraulic
valves, set timer to “constant” flow.

Electrical:

1.

Power must be connected directly to the bat-
tery. Make sure that eyelets are properly con-
nected (red to positive, black to negative).
Connect female socket to power port adapter.

Advertising