Great Plains YP1625 Operator Manual User Manual
Page 82
Advertising
1625
401-182M
7/12/2005
80
Figure 90
Figure 91
Figure 89
Refer to Figure 89
1.
Press Function key to advance to window
shown.
2.
If you wish to keep the Old number, perhaps
to re-run the calibration procedure, press the
Down arrow key. If you want to accept the
New calibration number, press the Up arrow
key.
Refer to Figure 90
3.
Console window now displays the calibration
number you have selected.
Refer to Figure 91
4.
This returns you back to the beginning of Cal-
ibration mode as shown. To re-run the Cali-
bration procedure, follow the steps outlined
above. It is suggested that you perform the
calibration mode at least twice, and additional
replications may be needed if Target and Ac-
tual amounts vary significantly.