Adjustments

51

2014-02-11

Table of Contents

Index

195-068M

Hydraulic opener down pressure controls drill-wide
opener penetration and press-wheel soil firming. Use
only enough down pressure to cut a furrow and maintain
proper soil-firming over seed. Excessive opener down
force may cause bulldozing of the openers in light soil
conditions, and leads to premature wear on opener
components.

The table at right shows the approximate force at
openers for a given pressure at the pressure control
valve.

Note: To account for additional compaction from drill and

tractor tires, set pressure on center openers slightly
higher than wing openers.

To run the drill with constant opener down pressure
requires an Active Hydraulic System. An Active Hydraulic
System requires a tractor with closed-center hydraulics
or pressure/flow compensated hydraulics powered by a
variable displacement hydraulic pump. (If you are not
familiar with your tractor’s hydraulics, consult your tractor
dealer.)

Machine Damage Risk: Tractors with load-sensing hydraulics
must use the bypass valve to operate the 3S-3000HD. Failure
to use the bypass valve can cause major tractor damage.
Before adjusting opener down pressure, set bypass valve per
Setting the Bypass Valve” on page 20.

Note: To run the drill on tractors with open-center hydrau-

lics or on tractors with fixed displacement hydraulic
pumps you must install a Great Plains kit, part num-
ber 194-143A. Contact your Great Plains dealer for
ordering information. See “Non-Active Hydraulic
System
” on page 33.

Pounds of Force at Opener Disks

Gauge

Setting

Row Spacing

6in

7.5in

10in

200 PSI

130

135

144

300 PSI

136

144

155

400 PSI

143

152

167

500 PSI

148

160

179

600 PSI

154

167

189

700 PSI

157

172

196

800 PSI

161

178

205

900 PSI

166

184

213

1000 PSI

171

190

223

1100 PSI

172

194

228

1200 PSI

180

203

240

1300 PSI

184

208

248

1400 PSI

189

215

258

1500 PSI

193

220

264

1600 PSI

198

227

274

1700 PSI

202

232

281

1800 PSI

209

240

291

1900 PSI

213

247

300

2000 PSI

217

253

309

2100 PSI

222

260

318

2200 PSI

227

266

327

2300 PSI

232

273

336