Motorola 3347 User Manual

Page 244

Advertising
background image

244

set ppp module [vccn] terminate-max

integer

Specifies the maximum number of unacknowledged termination requests that your Motor-
ola Netopia® Gateway will send before terminating the PPP link. The integer argument can
be any number between 1 and 10.

set ppp module [vccn] restart-timer

integer

Specifies the number of seconds the Motorola Netopia® Gateway should wait before
retransmitting a configuration or termination request. The integer argument can be any
number between 1 and 30.

set ppp module [vccn] connection-type { instant-on | always-on }

Specifies whether a PPP connection is maintained by the Motorola Netopia® Gateway
when it is unused for extended periods. If you specify always-on, the Motorola Netopia®
Gateway never shuts down the PPP link. If you specify instant-on, the Motorola Neto-
pia® Gateway shuts down the PPP link after the number of seconds specified in the time-
out

setting (below) if no traffic is moving over the circuit.

set ppp module [vccn] time-out

integer

If you specified a connection type of instant-on, specifies the number of seconds, in the
range 30 - 3600, with a default value of 300, the Motorola Netopia® Gateway should wait
for communication activity before terminating the PPP link.