Vermont Casting DBT36 User Manual

Page 12

Advertising
background image

DBT33/DBT36/DBT39

-12-

10002789/0

V

ERTICAL

S

IDEWALL

A

PPLICATIONS

Since it is very important that the venting system

maintain its balance between the combustion air

intake and the ue gas exhaust, certain limita-

tions as to vent congurations apply and must

be strictly adhered to.

The Vent Graph showing the relationship between vertical and

horizontal side wall venting will help to determine the various

dimensions allowable.

Minimum clearance between vent pipes and

combustible materials is one 1"(25mm) on top,

bottom and sides unless otherwise noted.

When vent termination exits through foundations less than 20"

below siding outcrop, the vent pipe must ush up with the

siding.
It is always best to locate the replace in such a way that

minimizes the number of offsets and horizontal vent length.
The horizontal vent run refers to the total length of vent pipe

from the ue collar of the replace to the face of the outer

wall.
Horizontal plane means no vertical rise exists on this portion

of the vent assembly.
• The maximum number of 90º elbows per side wall instal-

lation is three (3).

• If a 90º elbow is tted directly onto the replace ange

the maximum horizontal vent run before the termination

is 36" (914 mm).

• If a 90º elbow is used in the horizontal vent run (level

height maintained) the maximum horizontal vent length is

reduced by 36" (914 mm), (Fig. 20). This does not apply

if the 90º elbows are used to increase or redirect a vertical

rise (Fig. 21).

Example: According to the chart the maximum horizontal

vent length in a system with a 7.5' vertical rise is 20' (6 m)

and if a 90º elbow is required in the horizontal vent it must

be reduced to 17' (5.2 m).

In Fig. 20 Dimension A plus B must not be greater than

17' (5.2 m).

• The maximum number of 45º elbows permitted per side

wall installation is two (2). These elbows can be installed

in either the vertical or horizontal run.

• For each 45º elbow installed in the horizontal run, the

length of the horizontal run MUST be reduced by 18"

(45cm). This does not apply if the 45º elbows are

installed on the vertical part of the vent system.

• The maximum number of elbow degrees in a system is

270º (See Fig. 21).

Example: In Figure 21

Elbow 1 =

90º

Elbow 2 =

45º

Elbow 3 =

45º

Elbow 4 =

90º

Total angular variation = 270º

Fig. 18

Fig. 19

Fig. 20

Fig. 21