Vermont Casting DBT36 User Manual

Page 15

Advertising
background image

10002789/0

-15-

DBT33/DBT36/DBT39

DO NOT BACK FILL AROUND SNORKEL.
A CLEARANCE OF AT LEAST 4” MUST BE

MAINTAINED BETWEEN THE SNORKEL AND

THE SOIL

If the foundation is recessed, use recess brackets (not supplied)

for securing lower portion of the snorkel. Fasten brackets to

wall rst and then secure to snorkel with self-drilling #8 x 1/2

sheet metal screws. It will be necessary to extend the vent

pipes out as far as the protruding wall face (Fig. 29).

V

ERTICAL

T

HROUGH

-T

HE

-R

OOF

A

PPLICATIONS

.

This Gas Fireplace has been approved for,
• Vertical installations up to 40' (12 m) in height. Up to

a 10' horizontal vent run can be installed within the vent

system using a maximum of two 90º elbows. (Fig. 30)

• Up to two 45º elbows may be used within the horizontal

run. For each 45º elbow used on the horizontal level the

maximum horizontal length must be reduced by 18".

Example: Maximum horizontal length

0 x

45º elbows = 10'

1 x

45º elbow

= 8.5'

2 x

45º elbows = 7'

• A minimum of an 8' vertical rise.
• Two sets of 45º elbow offsets within these vertical instal-

lations. From 0 to a maximum of 8' of vent pipe can be

used between elbows. (Fig. 31)

Fig. 28