OX

The EB-1 Electrical junction box when tted and correctly

wired gives an easy and convenient power outlet for the

optioal fan kit.

If the EB-1 electrical junction box is being tted

the replace must be electrically connected and

grounded in accordance with local codes or, in

the absence of local codes, with the current CSA

C22.1 Canadian Electric Code.

For U.S.A. installations follow the local codes

and the national electrical code ANSI/NFPA No

70.

It is strongly recommended that the wiring of

the EB-1 Electrical Junction Box be carried out

be a licensed electrician.

Ensure that the power to the supply line has

been disconnected before commencing this pro-

cedure.

To install and connect the EB-1 box to the house electrical

supply follow the steps below.
1. Disconnect the power to the electrical supply line.
2. Remove the cover plate over the EB-1 knock-out the side

of the appliance, retain the screw that held the plate.

3. Remove the front cover of the EB-1 box.
4. Remove the plug socket assembly from the EB-1 box.
5. Feed the electrical supply line in through the EB-1 open-

ing in the side of the appliance and then through the back

of the EB-1 assembly, Fig ???.

6. Connect the ground wire of the supply line to the green

screw of the socket assembly.

7. Connect the white wire of the power line to the chrome

screw of the socket assembly.

8. Connect the black wire of the power supply line to the

brass screw (polarized) of the socket assembly.

9. Ret the socket assembly back into the electrical box and

replace the front cover plate. Secure the cable with the

clamp on the outside of the EB-1 base plate and ret the

EB-1 assembly to the appliance with the screw removed

in step 1.

F

AN

K

ITS

FK24 Fan Assembly

This auxiliary fan system increases the efciency of the circu-

lation of the heating air.
The FK24 fan kit allows variable speed control of the circula-

tion fan and also incorporates a heat sensor in the circuit.
Specications
115 Volt / 60 Hz / 56 Watts

Maintenance

The fan itself does not require regular maintenance, however

periodic cleaning of the fan and the surrounding area is

required.
Check the area under the control door (lower louvre assembly)

and in front of the fan and wipe or vacuum this area at least

once a month during the operating season.

Installation

The fan assembly and other components are supplied fully

wired eliminating the need for a licensed electrician to carry

out the installation
If hard wiring the fan using Method B (following) we strongly

recommend the use of a licensed electrician.
1 Open the lower Louvre assembly. Maneuver the fan &

bracket assembly around the gas valve and lines to locate

the unit onto the screw studs on the back of the replace

2 Install the thermal sensor under the bottom of the rebox,

locating it over the two 10 mm studs and secure it with

nuts.

Advertising