On/off s – Vermont Casting DBT36 User Manual

Page 7

Advertising
background image

10002789/0

-7-

DBT33/DBT36/DBT39

G

AS

L

INE

I

NSTALLATION

When purging the gas lines, the front glass must

be removed.

The gas pipeline can be brought in through the rear of the

replace as well as the bottom. Knockouts are provided on the

bottom behind the valve to allow for the gas pipe installation

and testing of any gas connection. It is most convenient to

bring the gas line in from the rear right side of the valve as

this allows fan installation or removal without disconnecting

the gas line.
The gas line connection can be made with properly tinned

3/8” copper tubing, 3/8” rigid pipe or an approved ex con-

nector. Since some municipalities have some additional local

codes it is always best to consult your local authority and the

CAN/CGA-B149 (.1 or .2) installation codes.
For U.S.A. Installations consult the current National Fuel Gas

Code, ANSI Z223.1

Always check for gas leaks with a mild soap and

water solution. Do not use an open ame for

leak testing.

The gas control is equipped with a captured screw type pres-

sure test point, therefore it is not necessary to provide a 1/8”

test point up stream of the control.
When using copper or ex connectors use only approved t-

tings. Always provide a union when using black iron pipe

so that the gas line can be easily disconnected for burner or

fan servicing. See the gas specication for pressure details

and ratings.
The replace valve must not be subjected to any test pressures

exceeding 1/2 p.s.i.. Isolate or disconnect this and any other

gas appliance control from the gas line when pressure testing.

R

EMOTE

ON/OFF S

WITCH

Installation

1. Thread the wiring through the holes on the end panels of

the appliance. Take care not to cut the wire or insulation

on metal edges. Route the wire to a conveniently located

receptacle box.

2. Attach the wire to the ON/OFF switch and install the

switch into the receptacle box.

3. Connect the other ends of the wire to the gas control valve

as shown in Fig. 6.

Alternative Switch Location

The remote switch can be installed on the front/side of the

access door. Simply mount the switch to the bracket provided

and screw the bracket to either side of the frame, lining up the

screws with the pre-punched holes, Fig. 7.

Do not wire the remote ON/OFF wall switch for

the gas replace to the 120 volt power supply.

Fig. 5

Fig. 6

Fig. 7

Advertising