• 7DVCS must be used to support offsets. (Fig. 36)This

application will require that you rst determine the roof

pitch and use the appropriate starter kit. (See Venting

Components List)

• The minimum height of the vent above the highest point

of penetration through the roof is 2'. See Fig. 38.

V

ERTICAL

R

ESTRICTOR

P

LATE

(DBT33

ONLY

)

When installing the DBT33 with a Vertical Through-The-Roof

congured ue system the restrictor plate, (#10002495) sup-

plied with the appliance MUST BE FITTED TO THE

APPLIANCE at installation.

Fitting The Restrictor Plate

1. Remove the window glass/frame assembly.
2. Locate the rebox bafe assembly in the top rear area of

the rebox, Fig. 32.

3. Remove the four (4) nuts along the front edge, and the

three (3) screws along the rear edge of the bafe assembly.

Remove the bafe assembly from the rebox.

4. Remove the two (2) screws from the top face of the bafe

assembly, Fig. 32. Place the restrictor plate as shown in

Fig. 34 and secure by retting the screws.

5. Ret the bafe assembly to the rebox, replacing the three

(3) screws and four (4) nuts.

6. Ret window glass/frame as per the appropriate sections

of this manual.