Vermont Casting DBT36 User Manual

Page 20

Advertising
background image

DBT33/DBT36/DBT39

-20-

10002789/0

G

ENERAL

O

PERATING

I

NSTRUCTIONS

G

LASS

I

NFORMATION

Only glass approved by CFM Majestic Inc.

should be used on this replace.

• The use of any non-approved replacement glass will void

all product warranties.

• Care must be taken to avoid breakage of the glass.
• Under no circumstances should this appliance be operated

without the front glass in place, or with the glass in a

damaged condition.

• Replacement glass (complete with gasket) is available

your dealer and should only be installed by a licensed

qualied service person.

G

ENERAL

M

AINTENANCE

Burner and Burner Compartment

It is important to keep the burner and the burner compartment

clean. At least once per year the logs and lava rock/ember

material should be removed and the burner compartment vacu-

umed and wiped out. Remove and ret the logs as per the

instructions in this manual.
Always handle the logs with care as they are fragile and may

also be hot if the replace has been in use.
FK24/FK12 Fan Assembly

The fan unit requires periodic cleaning. At least once per

month in the operating season open the lower louvre panels

and wipe or vacuum the area around the fan to remove any

build up of dust or lint.
Brass Trim

Clean the brass trim pieces using a soft cloth lightly dampened

with lemon oil. Do not use water or household cleaners on

any brass components.

L

OUVRE

R

EMOVAL

The top louvre panel is removed by lifting the panel vertically

and pulling it away from the appliance, Fig. 39.
The lower access door is hinged along the bottom edge and is

folded down to allow access.

G

LASS

/ F

RAME

R

EMOVAL

1. Turn the replace OFF (including the pilot).
2. If the unit has been operating allow time for the compo-

nents to cool.

3. Remove the top louvre assembly.
4. Open the lower louvre panel.
5. Release the two clamps securing the lower edge of the

frame by pulling down on the handles, Fig. 40.

6. Tilt the glass frame out slightly at the bottom, lift the

frame up and away rom the replace.

7. To replace the glass frame reverse the procedure.

G

LASS

C

LEANING

It is necessary to periodically clean the glass.
During start-up condensation, which is normal, forms on the

inside of the glass. This condensation causes lint, dust and

other airborne particles to cling to the glass surface.
Also initial paint curing may deposit a slight lm on the glass.
It is therefore recommended that the glass be cleaned two or

three times with a non-ammonia based household cleaner and

warm water (we recommend gas replace glass cleaner) within

the rst few weeks of operation.
After this initial cleaning process the glass should be cleaned

two or three times during each operating season depending on

the environment in the house.

Clean the glass after the rst two weeks of

operation.

Fig. 39

Fig. 40

Advertising
This manual is related to the following products: