-8-

10002789/0

C

ONVERTING

T

HE

A

PPLIANCE

F

ROM

LP

TO

N

ATURAL

G

AS

OR

N

ATURAL

G

AS

TO

LP.

The DBT33 is convertible between Natural Gas an LP gas

(and vice-versa) with the use of a conversion kit purchased

seperately, see your dealer for the correct part number.

The DBT36 & 39 can only be converted from

Propane to Natural gas.

The conversion of this appliance from one gas
to another must be carried out by an authorized

service provider.

1. Disconnect power to the unit and shut off the gas supply.
2. Remove the glass/frame assembly.
3. Carefully remove the logs & lava rock material
4. Remove the screws that are holding the burner housing

in place.

5. Remove the burner housing. Depending on the model of

the appliance you may have to loosen the pilot bracket

retaining screw/nut to allow the pilot and bracket assem-

bly to tilt and give enough clearance to remove the burner

housing.

6. Remove the main burner orice and replace it with the

orice supplied in the conversion kit.

7. SIT Top Convertible Pilot

Gently lift off the pilot hood from the pilot. (Do not

remove the spring clip holding the hood in place). Using

a correctly sized Allen key unscrew the exposed orice.

Insert the new orice supplied in the kit, do not over

tighten the orice. Replace the pilot hood ensuring the

index tab aligns with the notch on the hood.

PSE Pilot

Using a suitable wrench on the hexagonal body unscrew

the pilot hood assembly from the pilot, do not twist the

hood itself. Remove the orice and replace it with the

new orice supplied in the kit. Ret the pilot hood

assembly. Do not over-tighten the pilot hood. The hood

must return to its original alignment. Take care not to

damage the thermocouple, thermopile or igniter.

9. SIT 820 NOVA Gas Control Valve (Fig. 9)

a) Using a Torx T20 or slotted screwdriver, remove and

save the three pressure regulator mounting screws (A),

pressure regulator tower (B) and diaphragm (C).

b) Ensure the rubber gasket (D) is properly positioned and

install the new Hi/Lo pressure regulator to the valve using

the new screws (E) supplied with the kit. Tighten screws

securely. (Reference torque - 25 in.Lb).

c) Install the enclosed identication label (F) to the valve

body where it can be easily seen.

Honeywell Gas Control Valve (Fig. 10)

The Honeywell valve tted to this unit is suitable

for use with LP or Natural Gas. It is converted to

the required gas application by the installation of a

colour coded “conversion screw”.

a) Using a suitable small screwdriver lift out the central

regulator cap from the ‘Hi - Lo’ knob on the valve.

b) Unscrew the exposed conversion screw.

c) Insert the new colour coded conversion screw. Do not

over-tighten the screw, it must be nger tight.

d) Ret the regulator cap.

e) Mount the conversion label supplied with the conver-

sion screw to the valve in a visible position.

10. Reassemble the replace in the reverse order, except for

the front glass. Leave this off until the unit has been

checked for leaks and the gas supply line has been bled.

11. After bleeding the gas line and checking for leaks with a

soap solution, replace the front glass. Fire up the unit,

check for ame impingement on the logs, adjusting them

if necessary. Check the manifold and supply pressures

against the appliance specications.

The procedure for converting from one gas to

another is the same regardless of the initial gas

used. The only variation is in the orice sizes

and component part numbers. Your authorized

service provider will ensure the correct parts are

used.

Fig. 9