DBT33/DBT36/DBT39

-30-

10002789/0

W

IRING

I

NSTRUCTIONS

The replace, when installed, must be electri-

cally connected and grounded in accordance

with local codes or, in the absence of local

codes, with the current CSA C22.1 Canadian

Electric Code.

For U.S.A. installations follow the local codes

and the national electrical code ANSI/NFPA No

70.

Should this fan require servicing or repair the

power supply must be disconnected. For rewir-

ing of any replacement parts see Fig. 51

Any electrical re-wiring of this fan must be done

by a licensed electrician.

Method A

(Not using EB1, Fig. 51)

1. Connect the ground wire of the power supply line to the

ground stud located on the base of the rebox.

2. Connect the black wire of the supply line to either termi-

nal of the speed control unit.

3. The second terminal of the speed control unit is attached

to either terminal of the thermal sensor.

4. The second terminal of the thermal sensor is connected to

either terminal of the fan motor.

5. The second fan motor terminal is connected to the white

wire of the supply line.

Method B

(Using the EB-1 Box

.

For instruction on wiring the EB-1 Electrical Junction Box see

the chapter EB-1 Electrical Box.

Fig. 51

3 Locate the fan speed control unit. This can be tted

behind the lower louvre assembly as in Fig. 50 or located

remotely in a conveniently located wall mounted electrical

box. Remote location of the speed control will require

suitable extension of the component wiring.

4 The power supply may be connected in 2 ways:

Method A

Route the 6' lead tted to the unit to a conveniently

located wall socket.

Method B

The EB1 receptacle box (Pt. # ZA1200) may be hard

wired into the house supply. The fan lead is then plugged

into the EB1 box.

Fig. 50

FK12

This auxiliary fan system increases the efciency of the circu-

lation of the heating air.
The FK12 Fan Assembly is a xed speed fan system and does

not allow for variable speed control. It does not use the speed

control unit or the heat sensor used in the FK24 Kit.
Specications
115 Volts / 60 Hz / 56 Watts.

Maintenance

The fan itself does not require regular maintenance, however

periodic cleaning of the fan and the surrounding area is

required.
Check the area under the control door (lower louvre assembly)

and in front of the fan and wipe or vacuum this area at least

once a month during the operating season.

Installation

The fan assembly is supplied fully wired eliminating the need

for a licensed electrician to carry out the installation
1. Open the lower Louvre assembly. Maneuver the fan &

bracket assembly around the gas valve and lines to locate

the unit against the back wall of the appliance, resting on

the base.

2. With the protective cover removed from the self-adhesive

‘Velcro’ strips apply mild pressure to the fan & bracket

unit to secure the strips to the metal panels. No further

securing is required.

3. Power to the fan can be supplied by plugging the supplied

lead into a conveniently located wall socket or by using a

hard-wired EB1 connector box.